RS-232 Interface
Enter/Exit Programming Mode

Data Bits

This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII pro-
tocol for sending and receiving data.
$CR2DA00(CR)
7 Data Bits
$CR2DA01(CR)
DEFAULT
8 Data Bits

Stop Bits

Set the number of stop bits to match host device requirements. See
page 232
for more infor-
mation on this feature.
$CR2ST00(CR)
DEFAULT
1 Stop Bit
$CR2ST01(CR)
2 Stop Bits
Product Reference Guide