Enter/Exit Programming Mode

I 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in
Fixed Length Mode. The length includes the bar code's check and data characters. The length
can be set from 2 to 50 characters in increments of two.
Table 7
provides some examples for setting Length 1. See
setting this feature.
Table 7. I 2 of 5 Length 1 Setting Examples
STEP
ACTION
1
Desired Setting
Pad with leading zeroes to
2
yield two digits
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 of 5 LENGTH 1 SETTING
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
132
EXAMPLES
2 Characters
02
'0' and '2'
06 = Length 1 is 6 Characters
DEFAULT
Interleaved 2 of 5 (I 2 of 5)
I 2 of 5 Length Control on page
page 243
for detailed instructions on
6 Characters
14 Characters
06
14
'0' and '6'
'1' and '4'
~
CANCEL
QuickScan™ I QD24XX/QBT24XX/QM24XX
131.
50 Characters
50
'5' AND '0'