EPSON Stylus PHOTO RX560/580/590
5.3.2 Adjustment Procedure
5.3.2.1 BRS adjustment
Printing the BRS adjustment pattern
1.
Set an A4 sheet of Matte Paper-Heavyweight on the paper support.
2.
Select "BRS adjustment" on the adjustment program.
3.
Print the adjustment pattern by clicking the [Print] button of "1. Print the
adjustment pattern".
4.
Wait for more than five minutes to dry the printed pattern.
C H E C K
The adjustment program, using the unit identification code,
P O I N T
judges whether the printer for which the correction value is
registered is the same one that was used to print the adjustment
pattern.
When a scanner with a CIS system is to be used to read the
adjustment pattern, wait for more than five minutes to dry the
printed pattern and then start scanning.
When a scanner with a CCD system is to be used, the printed
pattern can be read without waiting for drying after printing.
(See Table 5-4. Specified Scanner for BRS/PFP Adjustment (p.
77))
Adjustment
Banding Reduction System (BRS) Adjustment / Paper Feed Profile Correction (PFP)
Unit identification code
Figure 5-7. BRS Adjustment Pattern
Revision A
79