4.2.2 Disassembly of Panel Assy

C A U T I O N
Take great care that the LCD surface is kept free from scratches
or dust and dirt.
In installation, make sure that the inside of the LCD Cover is free
from dust and dirt.
1.
Remove the Panel Assy (p.42)
2.
Remove the screws (x6) securing the Shield Plate, Panel Board and Ground Plate,
and remove the Shield Plate upward. (Fig. 4-4)
3.
Release the hooks, and remove the Panel Board. (Fig. 4-5)
4.
Remove the screws (x2), and remove the LCD Module. (Fig. 4-6)
Tighten the screws for the LCD Module in the order specified.
(Fig. 4-6)
Install the Shield Plate under the board-to-board cable.
When installing the Shield Plate, tighten the screws in the order
specified. (Fig. 4-4)
After installing the Shield Plate, press each of the buttons and
check that a click is felt.