Reading the PFP adjustment pattern
4.
Set the reference scale and the printed BRS adjustment pattern, which must be
dried for more than five minutes beforehand, on the scanner and press the
[Read] button of "3. Read the adjustment pattern".
5.
The PFP correction value will be automatically calculated based on the read
adjustment pattern and be written on the serial flash ROM.
In case an error has occurred, check and make sure that the document table
glass and the reference scale are free from dust and dirt and the reference scale
and adjustment pattern are not on a slant. Then repeat the procedure from step
4 above.
C A U T I O N
When setting the reference scale and adjustment pattern on the
scanner, observe the following instructions:
Position the top right corner of the reference scale at the
scanner origin and set the reference scale in such a position
that its right side is in close contact with the document table
glass end.
Place the adjustment pattern along the reference scale as
shown at right. In doing so, position the adjustment pattern so
that it is in parallel with the reference scale and there is no
clearance between them.
Adjustment
Banding Reduction System (BRS) Adjustment / Paper Feed Profile Correction (PFP)
Scanner origin
PFP adjustment pattern (Size 4x6)
PFP reference scale
Scanner document table
Figure 5-10. Positioning the Reference Scale and PFP Adjustment Pattern