16. Strobe White Balance Adjustment

Adjust the white balance when the strobe light flashed.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Perform "Hall Adjustment", "Flange Back Adjustment",
"Light Level Adjustment" and "Auto White Balance Ad-
justment" before this adjustment.
Note 2: Perform this adjustment in the flash adjustment box.
Note 3: Refer to "4. Preparing the Flash Adjustment Box".
(See page 5-7)
Note 4: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of the unit OFF/ON.
Note 5: "Strobe White Balance Adjustment" is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1)
FLASH ......................
Adjusting method:
Order Page Address Data
1
0
01
01
2
5
F1
FF
3
D
63
40
4
5
6
90
00
6
6
91
00
7
6
92
00
8
6
93
C0
9
6
6C
01
10
6
2C
01
11
6
01
79
12
6
01
67
13
6
02
14
6
01
00
15
6
01
79
16
6
01
67
17
6
02
18
6
01
00
19
6
01
79
20
6
01
B9
21
6
02
22
Note 6: The adjustment data will be automatically input to
page: F, address: 4D, 4E, 64, 69, 6A and 6B.
CAMERA
Flash adjustment box (Note 3)
(1.0 m from the front of lens)
F
4D, 4E, 64, 69, 6A, 6B
ON
Procedure
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Press PAUSE button.
Press PAUSE button.
Check the data changes to "01".
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Check the data changes to "01".
Press PAUSE button.
Press PAUSE button.
Press PAUSE button. (Note 6)
Check the data changes to "01".
Perform "Strobe Light Level
and White Balance Check"
5-30