5. F No. Standard Data Input

Compensate the unevenness of the iris meter sensitivity.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: "F No. Standard Data Input" is available only once after
the power is turned on. Turn the power off, then on again
if the adjustment is retried.
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
5
F1
FF
4
D
63
40
5
6
E
51
7
E
51
FF
8
6
01
BB
9
6
02
Note 3: The adjustment data will be automatically input to page:
F, address: 29 to 2C.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
E
51
3
5
F1
00
4
D
63
00
5
6
0
01
00
CAMERA
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
F
29 to 2C
Procedure
Shoot the Clear chart with
the zoom WIDE end.
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Note down the data.
Press PAUSE button.
Press PAUSE button.
(Note 3)
Check the data changes to
"01".
Procedure
Press PAUSE button.
Set data noted down at step 6,
and press PAUSE button.
Press PAUSE button.
Release the data setting
performed at step 5.
(Refer to page 5-14)

6. Mechanical Shutter Adjustment

Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
Subject
Adjustment Page
Adjustment Address
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
1
2
0
01
3
5
F1
4
D
63
5
6
6
01
7
6
02
8
6
AB
Note 2: The adjustment data will be automatically input to page:
F, address: 5A and 6C to 7F.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
5
F1
3
D
63
4
5
0
01
5-19
CAMERA
Clear chart
(10 cm from the front of the lens)
F
5A, 6C to 7F
Procedure
Shoot the Clear chart with
the zoom WIDE end.
01
FF
40
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
AD
Press PAUSE button (Note 2)
Check the data changes to
"01".
Check the data.
00 : Normal
01 to FF : Defective
Procedure
00
Press PAUSE button.
00
00
Press PAUSE button.
Release the data setting
performed at step 5.
(Refer to page 5-14)