Strobe White Balance Adjustment - Sony DSC-P51M Service Manual

Digital still camera
Table of Contents

Advertisement

19. Strobe White Balance Adjustment

Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(1 m from the front of lens)
Measurement Point
Displayed data of page: 1 (Note
4) and page: F, address: E8, EA,
EC, EE
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
B6, B7, DB to EF
Specified Value
Y level data: 03 to 07
R-Y level data:
007A to 0086 (Note 4)
B-Y level data:
007A to 0086 (Note 4)
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Perform this adjustment in the Flash adjustment box.
Note 3: Refer to "4. Preparing the Flash adjustment box".
(See page 5-7)
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Note 5: "Strobe White Balance Adjustment" is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1) FLASH (Control button) .............. ON
Adjusting method:
Order Page Address Data
1
2
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
FF
7
6
93
FF
8
6
6C
01
9
6
01
79
10
6
07
11
6
01
67
12
13
6
02
14
F
E8
15
6
01
00
16
6
01
67
RadarW
RadarW
RadarW
RadarW
RadarW
Displayed data
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
Perform "Picture Frame
setting ". (Refer to page 5-
14)
Press PAUSE button.
Check the data changes to
"01".
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
Check that the displayed data
satisfies the Y level specified
value.
Press PAUSE button.
Press PAUSE button.
Order Page Address Data
17
18
6
02
19
6
01
20
6
01
21
22
6
02
23
6
01
24
6
01
25
26
6
02
27
6
01
28
6
01
29
30
6
02
31
6
01
32
6
01
33
34
6
02
EA
35
F
EC
EE
36
37
0
03
38
1
39
0
03
40
1
Note 6: The adjustment data will be automatically input to page:
F, address: B6 to B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
90
3
6
91
4
6
92
5
6
93
6
6
2C
7
6
6C
8
0
03
9
5-29
DSC-P51/P51M
Procedure
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
67
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
67
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
B9
Press PAUSE button. (Note 6)
Check the flashing.
Check the data changes to
"01".
00
Press PAUSE button.
E7
Press PAUSE button. (Note 6)
Check the flashing.
Check the data changes to
"01".
Check that the displayed data
satisfies the Y level specified
value.
Wait for 1 second.
2C
Check that the R-Y level data
(Note 4) satisfied the
specified value.
2D
Check that the B-Y level data
(Note 4) satisfied the
specified value.
Procedure
00
Press PAUSE button.
00
00
00
00
00
00
00
Release the data setting
performed at step 1.
(Refer to page 5-13)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc-p51

Table of Contents