Flange Back Check - Sony MVC-FD97 Service Manual

Digital still camera
Hide thumbs Also See for MVC-FD97:
Table of Contents

Advertisement

3-2. Flange Back Adjustment (2)
Perform this adjustment after performing "Flange Back Adjust-
ment (1)".
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
5
F1
FF
4
D
63
40
5
6
6
01
13
7
8
6
01
29
9
6
02
Note 1: The adjustment data will be automatically input to
page: F, address: 14 to 25.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
5
F1
00
3
D
63
00
4
5
0
01
00
6
CAMERA
Subject more than 500 m away
(Subjects with clear contrast such
as buildings, etc.)
Check operation on the LCD
screen
F
14 to 25
Procedure
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away (subject with clear
contrast such as building,
etc.). (Nearby subjects less
than 500 m away should not
be in the screen)
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Press PAUSE button.
Place the ND filter on the
lens so that the optimum
image is obtain.
Press PAUSE button. (Note 1)
Check the data changes to "01".
Procedure
Press PAUSE button.
Press PAUSE button.
Release the data setting
performed at step 5.
(Refer to page 5-14)
Perform"Flange Back Check".

4. Flange Back Check

Mode
Subject
Measurement Point
Measuring Instrument
Specified value
Checking method:
Order Page Address Data
1
2
0
01
3
5
F1
4
D
63
5
6
7
8
6
2C
9
Processing after Completing Adjustment:
Order Page Address Data
1
6
2C
2
5
F1
3
D
63
4
5
0
01
5-18
CAMERA
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Check operation on the LCD
screen
Focused at the TELE end and
WIDE end
Procedure
Place the Siemens star 2.0 m
from the front of the lens.
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
01
FF
40
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Shoot the Siemens star with
the zoom TELE end.
Check that the lens is
focused.
01
While observe the LCD
screen, change the zoom to
the WIDE end and check that
the lens is focused.
Procedure
00
00
00
Press PAUSE button.
Release the data setting
performed at step 5.
(Refer to page 5-14)
00