2-3.

SERVICE MODE

1. Setting the Test Mode

Page D
Data
00
Normal
01
Forced CAMERA mode power ON
02
Forced PLAY mode power ON
03
Forced MOVIE mode power ON
• Before setting the data, select page: 0, address: 01, and set data:
01.
• For page D, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjusting remote com-
mander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to "00", and press the PAUSE button of the ad-
justing remote commander.
Select page: 0, address: 01, and set data: 00.

2. Bit Value Discrimination

Bit values must be discriminated using the display data of the ad-
justing remote commander for following items. Use the table be-
low to discriminate if the bit value is "1" or "0".
Display on the adjustilng remote commander
0 : 00 : 00
Page
Display on the
Adjusting
bit3
remote
or
commander
bit7
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
1
A
9
1
A (A)
1
B (b)
1
C (c)
1
D (d)
1
E (E)
1
B
F (F)
1
Example: If "8E" is displayed on the adjusting remote com-
mander, the bit values for bit7 to bit4 are shown in the
A column, and the bit values for bit3 to bit0 are shown
in the B column.
Address 10
Function
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Bit values
bit2
bit1
bit0
or
or
bit6
bit5
bit4
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1

3. Switch Check (1)

Page 2
Bit
Function
XPOWER SW
0
(PK-55 board S703)
XCAM/PLAY SW
1
(PK-55 board S707)
SHUTTR SW
(CONTROL SWITCH
2
BLOCK S001)
XSHUTTER LOCK SW
(CONTROL SWITCH
3
BLOCK S001)
MEMORY STICK
4
IN SW (MS Socket)
5
6
7
XSTILL/MOVIE SW MOVIE
(PK-55 board S709)
Using method:
1) Select page: 2, address: 43.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.

4. Switch Check (2)

Page 2
Bit
Function
DISK/XMS SW
0
(FC-85 board S401)
Using method:
1) Select page: 2, address: 48.
2) By discriminating the bit value of dispaly data, the state of the
or
switches can be discriminated.
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
5-53
Address 43
When bit value=1 When bit value=0
OFF
ON
PLAY
CAMERA
OFF
ON
OFF
ON
OUT
IN
STILL
Address 48
When bit value=1 When bit value=0
MEMORY
FLOPPY DISK
STICK