Strobe White Balance Adjustment - Sony DSC-P30 Service Manual

Table of Contents

Advertisement

17. Strobe White Balance Adjustment

Adjust the white balance when the strobe light flashed.
Mode
Subject
Adjustment Page
Adjustment Address
Specified Value
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Perform this adjustment in the Flash adjustment box.
Note 3: Refer to "4. Preparing the Flash adjustment box". (See
page 5-7)
Note 4: Displayed data of page: F, address: 64, of the adjusting
remote commander.
F:XX:64
Note 5: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Note 6: "Strobe White Balance Adjustment" is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1) FLASH ........................ ON
CAMERA
Flash adjustment box (Note 3)
(1.0 m from the front of the lens)
F
4D, 4E, 64, 69 to 6B
Y level data: 60 to 94 (Note 4)
R-Y level data: FA to FF or 00 to 06
(Note 5)
B-Y level data: FA to FF or 00 to 06
(Note 5)
Y level data
B-Y level data
R-Y level data
Adjusting method:
Order Page Address Data
1
0
01
2
3
6
90
4
6
91
5
6
92
6
6
93
7
6
2C
8
6
01
9
6
07
10
6
01
11
12
6
02
13
6
01
14
6
01
15
16
6
02
17
6
01
18
6
01
19
20
6
02
21
6
01
22
6
01
23
24
6
02
25
F
64
26
0
03
27
1
Note 7: The adjustment data will be automatically input to page:
F, address: 4D, 4E, 64 and 69 to 6B.
Processing after Completing Adjustment:
Order Page Address Data
1
0
03
2
6
01
3
6
2C
4
6
92
5
6
93
6
7
0
01
5-29
Procedure
01
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
00
00
FF
FF
01
79
Press PAUSE button.
Check the data changes to "01".
67
Press PAUSE button.
Check the flashing of strobe
light.
Check the data changes to "01".
00
Press PAUSE button.
67
Press PAUSE button.
Check the flashing of strobe
light.
Check the data changes to "01".
00
Press PAUSE button.
B9
Press PAUSE button. (Note 7)
Check the flashing of strobe
light.
Check the data changes to "01".
00
Press PAUSE button.
67
Press PAUSE button.
Check the flashing of strobe
light.
Check the data changes to "01".
Check that the data satisfies
the Y level data satisfied
value. (Note 4)
02
Check the R-Y and B-Y level
data (Note 5) satisfies the
specified value.
Procedure
00
00
Press PAUSE button.
00
00
00
Release the data setting
performed at step 2 . (Refer
to page 5-14)
00