Cj, C4, 81, 80, Hc, H1" Thermistor Or Related Abnormality (Hydro-Box) - Daikin ESIE13-02 Service Manual

Table of Contents

Advertisement

Error Codes: Hydro-box

"CJ, C4, 81, 80, HC, H1" Thermistor or Related Abnormality (Hydro-box)

3.3
1
User interface
display
Method of
malfunction
detection
Malfunction
decision conditions
3
Supposed causes
4
Troubleshooting
5
Part 4 – Troubleshooting
CJ, C4, 81, 80, HC, H1
The temperatures detected by the thermistors are used to determine thermistor errors.
When the thermistor input is more than 4.96 V or less than 0.04 V during compressor operation*.
* (reference)
When above about 212°C (less than 120 ohms) or below about –50°C (more than 1,860 kOhms).
Note: The values vary slightly in some models.
Faulty connector connection
Faulty thermistor
Faulty PCB
Check the connector connection.
Is it normal?
YES
Check No. 04
Thermistor resistance check
Is it normal?
YES
CJ : Room temperature thermistor
HC:
Tank temperature thermistor
C4:
Hydro-box heat exchanger thermistor
81:
Leaving water temperature thermistor
80:
Return water temperature thermistor
(*) See also "Check No.4 - Resistance Conversion Table (Ambient, Coil, Fin)" on page 153.
NO
NO
96
ESIE13-02
Correct the connection.
Replace the thermistor.
(Replace the hydro-box PCB.)
Replace the hydro-box PCB.