ESIE13-02
2.3

Solving Problems Based on Error Codes

When a problem happens, an error code appears on the user interface. It is important to understand
the problem and to take countermeasure before resetting the error code. This should be done by a
licensed installer or by your local dealer.
This chapter gives you an overview of all error codes and the content of the error code as it appears
on the user interface.
For a more detailed troubleshooting guideline for each error, please see the service manual.
2.3.1
Error codes: Overview
Error codes of the
The controller on the gas boiler detects faults and indicates them on the display by error codes.
gas boiler
If the LED is flashing, the controller has detected a problem. Once the problem is rectified, the
controller can be restarted by pressing the
Following table shows a list of error codes and the possible solutions.
Error
code
10, 11,
12, 13,
14
20, 21,
22, 23,
24
0
1
2
4
Cause
Sensor fault S1.
Flow sensor cannot close.
Sensor fault S2.
Sensor fault after self-check.
Temperature too high.
S1 and S2 interchanged.
No flame signal.
87
Error Codes: Gas Condensing Boiler
button.
f
Possible solution
Check wiring.
Replace S1.
Check flow switch.
Check wiring.
Replace S2.
Replace S1 and/or S2.
Air in installation.
Pump is NOT running.
Insufficient flow in installation.
Radiators are closed.
Pump setting is too low.
Flow switch is sticking.
Check cable set.
Replace S1 and S2.
Gas tap is closed.
No or incorrect ignition gap.
Gas supply pressure is too low or fails.
Gas valve or ignition unit is NOT powered.
Part 4 – Troubleshooting
4
3
4
4
5