1.2.12 The User Interface Does Not Display Certain Screens (RT, LWT, Tank, Ext RT)
EHB*CA, EHV*CA
Applicable models
Error detection
method
Error generating
condition
Supposed causes -
corrective action
Possible causes
The tank-screen is not visible.
The RT-screen is not visible.
The ext RT-screen is not visible.
The LWT-screen is not visible.
Corrective action
Check if there is a tank connected? Then setting
A.2.2.1. should be set to yes.
Check setting A.2.1. to see if unit control method
is set to Room Thermostat control.
Check setting A.2.1. to see if unit control method
is set to ext Room Thermostat control.
1. Check setting A.2.1. to see if unit control
method is set to LWT.
2. Check 7.4.1 (user settings - available home
page if LWT screen is enabled).