Electrical Connections - HearthStone Tribute DV 8050 Owner's Manual And Installation Manual

Gas-fired directvent heater
Hide thumbs Also See for Tribute DV 8050:
Table of Contents

Advertisement

HearthStone Quality Home Heating Products, Inc.
I
I
NSTALLATION
NSTRUCTIONS
S
FOR THE
TANDARD
T
M
ERMINATION
V
K
ENTING
IT
1. Install the straight over the outer
collar.
2. Move the stove and pipe assembly
back until the straight is flush to the
wall. Pull up on the pipe to ensure
that there is a ¼" per foot rise
coming out of the stove.
3. Draw a circle around the pipe. Use
the center of this circle as the center
point of the 10" x 10" square wall
pass through. Cut and frame the wall
pass through.
4. Place the interior wall thimble into
the 10" x 10" wall pass through.
Secure it with 4 screws (not
provided). Install the exterior portion
of the thimble in similar fashion,
overlapping the 2 sections.
E
LECTRICAL
NOTE: OPEN VALVE DOOR IN THE LOWER FRONT FOR ELECTRICAL AND GAS
CONNECTIONS.
T
HERMOSTAT
The ON/OFF/T'stat switch or wall mounted
thermostat controls the Tribute DV.
recommend installation of the thermostat for
more comfortable performance, however
you may still override the thermostat by
setting the switch to "ON". The thermostat
controls the unit by "calling for heat." The
thermostat turns the unit on when the room
H
ORIZONTAL
INIMUM
C
ONNECTIONS
We
• Caution: For building with vinyl siding,
a vinyl siding standoff should be
installed between the vent cap and the
exterior wall.
5. Install
termination on the outside of the
wall. Make sure both of the retaining
straps extend through interior wall
thimble. Before attaching the vent
termination to the outside of the
house, run a bead of non-hardening
mastic around its' outside edges, so
as to make a seal between it and the
wall. The arrow on the end cap
should point up. Secure the cap to
the wall with the appropriate screws.
7.
Move the stove and vent pipe into
position. Make sure the vent pipe
extends into the horizontal vent cap a
minimum of 1-1/4").
8.
Secure the vent using the straps from
the horizontal vent termination to the
interior pipe with 2 sheet metal
screws, keeping the screws close to
the wall thimble as possible. Bend or
cut the excess strapping, so that it is
not visible after the installation is
complete.
is cold, and turns the unit off once the room
is warmed sufficiently. The thermostat is
controlled by a 750 millivolt DC two-wire
circuit.
R
C
EMOTE
ONTROL
There are two different optional remote
controls available for the Tribute DV. Both
of the remote controls are capable of turning
14
Tribute DV Model #8050
the
horizontal
vent

Advertisement

Table of Contents
loading

Table of Contents