Electrical Connections - HearthStone Killington Owner's Manual

Gas-fired direct vent insert heater
Table of Contents

Advertisement

OWNER'S MANUAL
co-linear to co-axial adaptor is the pipe that is in the
center of the adaptor.)
 Repeat this process to the top outer edge of both the
intake and exhaust collars on the back of the unit.
The exhaust adaptor is the collar nearest the center
of the unit, the intake adaptor collar is on the right
side of the stove (refer to
Figure 5 on page 8).
necessary(refer to Figure 3 on page 7). Slide a hose
clamp over the ends of both flexible vent pipes.
Place the flexible vent pipe marked "intake" onto the
intake collar, place the flexible vent pipe marked
"exhaust" onto the exhaust collar. Secure them to
the collar adaptors by tightening the hose clamps
with a slotted screwdriver or 5/16" nut driver.
The following guidelines must be observed when
installing the vent pipes:
Do not install the venting into a chimney
serving another appliance, be it fossil fuel,
solid fuel, or another gas.
Do not crimp or rupture the vent pipes.
Both the Exhaust and Intake vent pipes must
reline the entire length of the chimney. The
exhaust and inlet vents must terminate
above the top of the chimney using the
appropriate vent termination components
listed in these instructions.
2.Using the existing chimney as an air inlet
The following installation procedure is not
covered under the ANSI Z21.88 test
method and product certification. Use of an
existing chimney as an air intake must be
specifically approved by your gas supplier
and the local code Authority Having
Jurisdiction.
The chimney flue must be carefully sealed from the
room environment. Fabricate a plate of non-
combustible material and carefully fit it to the
damper area with high temperature sealant.
This stove is certified for use with a coaxial
venting system. ANSI Z21.88 standards state
that the maximum leakage rate for the venting
system is 32 SCFM @ .06" w.c. This leakage
must be accounted for if you use the chimney for
intake air.
Figure 1
, on page 5 &
Install the restrictor if
Chimney Liner
Termination Kit (Exhaust to center connector)
NOTE: All joints must be sealed. Leakage around
the damper seal must be avoided.
WARNING: This installation may not work in a
negative pressure environment, or if a seal
cannot be attained. If sooting, ghosting of flame
occurs, please check and repair leakage of
chimney system.

ELECTRICAL CONNECTIONS

NOTE: OPEN VALVE DOOR ON THE CENTER
BOTTOM OF THE FRONT FOR ELECTRICAL
AND GAS CONNECTIONS
Electrical Grounding Instructions
9
Model # 8870 Killington
Exhaust
3" Co-Linear Flex
Extensions(exhaust must be within 10'-40')
Non-combustible damper
seal:
1) Must support inlet flex pipe
2) Musr seal chimney opening around
inlet and exhaust flex pipe
Inlet:
Must extend through the damper seal