HearthStone Killington Owner's Manual

Gas-fired direct vent insert heater

Advertisement

DVI-32/Killington (8870)
GAS-FIRED DIRECT VENT INSERT
FOR YOUR SAFETY:
gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY:
Smell Gas:
Do not touch electrical switches.
Do not try to light any appliance.
Do not use the phone in your building.
Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
If you cannot reach your gas supplier, call the fire
department.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance
or additional information consult a qualified, service
agency, or the gas supplier
HEATER
Do not store or use
What To Do If You
.
Manufactured by HearthStone
317 Stafford Avenue
Morrisville, Vermont 05661
E-Mail-Inquiry@HearthStoneStoves.com
READ THIS OWNER'S MANUAL
Operate and maintain this gas heater
according to instructions in this manual.
Read this manual in its entirety.
POUR VOTRE SÉCURITÉ:
ni utiliser d'essence ni d'autre vaperurs ou liquides
inflammables dans le voisinage de cet apprareil ou de
tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous
sentez une odeur de gaz
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur.
servir des téléphones se trouvant dans le
batiment où vous vous trouvez.
Evacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
AVERTISSEMENT:
une modification, un entretien ou une maintenance
incorrects peuvent entrâiner des dommages matériels,
des lésions corporelles ou la perte de vies humaines.
Consulter le manuel des usagers fourn avec ce
générateur d'air chaud.
Ne pas entresposer
:
Ne pas vous
Une installation, un réglage,
10-23-02 6400-1204

Advertisement

Table of Contents
loading

Summary of Contents for HearthStone Killington

  • Page 1 DVI-32/Killington (8870) GAS-FIRED DIRECT VENT INSERT HEATER Manufactured by HearthStone 317 Stafford Avenue Morrisville, Vermont 05661 E-Mail-Inquiry@HearthStoneStoves.com READ THIS OWNER’S MANUAL Operate and maintain this gas heater according to instructions in this manual. Read this manual in its entirety. POUR VOTRE SÉCURITÉ:...
  • Page 2: Information Sheet

    Date of Purchase: ________________ Installed by: _____________________________________ Phone: Date of Installation: _______________ Gas Supplier: _____________________________________ Phone: ____________________ Read this Owner’s Manual before installing or operating the Killington heater. Retain this manual for future reference. Service Record Date Who Performed Work Work Performed...
  • Page 3: Table Of Contents

    OWNER’S MANUAL Model # 8870 Killington TABLE OF CONTENTS INFORMATION SHEET ..................................1 Service Record ....................................1 TABLE OF CONTENTS..................................2 CODES .........................................2 INTRODUCTION ....................................3 SAFETY INFORMATION ..................................3 SPECIFICATIONS....................................5 UNPACKING.......................................6 CLEARANCES TO COMBUSTIBLES...............................7 HEARTH REQUIREMENTS /FLOOR PROTECTION........................7 VENTING COMPONENTS & CONFIGURATION ...........................7 Restrictor Disc ....................................7 Venting System Installation ................................8...
  • Page 4: Introduction

    Do not store or use gasoline or other flammable vapors material, etc. It is imperative that control or liquids in the vicinity of this appliance. The Killington compartments, burners, and circulating air should be located out of traffic and away from furniture, draperies, clothing, and flammable material.
  • Page 5 National Fuel Gas SERVICE CAUTION Code, ANSI Z223.1 (NFPA 54). If you believe your Killington is not, in any way, performing properly, immediately discontinue operation Do not use this appliance if any part has been under until the unit has been inspected and approved by water.
  • Page 6: Specifications

    1 9 3 /4 " Listed: 16" 15 1/4" Direct Vent Gas Fireplace Model: TOP VIEW S ID E V IE W Killington Direct Vent Insert Room Heater 4 4" 38" Testing Agency: Intertek Testing Services NA Inc. (ITS) 3 1 3 /4"...
  • Page 7: Unpacking

    OWNER’S MANUAL Model # 8870 Killington UNPACKING Inspect for Damage The Killington is packaged by the manufacturer to withstand shipment, without damage, under most Inspect the Killington for visible and/or concealed circumstances. However, damage can occur during damage. The unit should appear to be square and true.
  • Page 8: Clearances To Combustibles

    VENTING COMPONENTS & CONFIGURATION The Killington cannot be vented jointly with any other solid fuel or gas appliance. The Killington must be vented directly to the outside of the building using a proper termination as listed below. The venting Figure 3: Restrictor configuration is shown in Figures 4 &...
  • Page 9: Venting System Installation

    Before You Begin Make sure the masonry fireplace and flue comply with Fireplace the applicable codes and are in good condition. Repair any damage before installation of the Killington begins. *INSULATION Prepare a zero clearance (metal) fireplace by doing the following: -Place the label provided on the Z.C.
  • Page 10: Electrical Connections

    OWNER’S MANUAL Model # 8870 Killington co-linear to co-axial adaptor is the pipe that is in the Chimney Liner center of the adaptor.) Termination Kit (Exhaust to center connector)  Repeat this process to the top outer edge of both the intake and exhaust collars on the back of the unit.
  • Page 11 The fireplace insert is operated by the on/off/thermostat Thermostat Placement switch. The Killington may also be controlled by the The thermostat should be placed in the same room or wall mounted thermostat for automatic operation. We living space as the unit. Typically 5' (1.5 m) off the...
  • Page 12: Gas Supply And Connections

    Consult all local codes. rear right portion of the Killington. Apply a thread sealant to both male ends on the flexible gas line. WARNING: The unit must be installed and connected...
  • Page 13: Assembling The Unit

    OWNER’S MANUAL Model # 8870 Killington The logs set and an ember screen must be placed in the firebox at their precise location. Remove the front glass as described in the Inspect for Damage section of this manual, on page 6. Using the “locator” tabs on the...
  • Page 14 OWNER’S MANUAL Model # 8870 Killington WARNING: Failure to position the parts in accordance with the Figures in this manual, or failure to use only parts specifically approved with FRONT CAST ASSEMBLY this appliance may result in property damage or...
  • Page 15: Lighting The Unit For The First Time

    Initial Adjustments Place a level on the top of the unit. Two leveling leg Once the Killington has been set in place, connected and bolts are located in the front of the base plate. Use a assembled as described in the Assembly Of The Unit, wrench to turn these bolts up or down as necessary to Electrical Connections, and Gas Supply &...
  • Page 16: Turning Off The Unit

    OWNER’S MANUAL Model # 8870 Killington to “OFF”. thermostat, turn the thermostat to “ON” and set it to a 4. Wait (5) five minutes to clear out any gas. If higher position so that it “calls” for heat (i.e. turns the you then smell gas, STOP!, immediately follow unit on).
  • Page 17: Pilot Adjustment

    To adjust the air shutters, DAILY OPERATION open the valve control door and locate the shutter The Killington gas-fired heater is easily operated by the position indicator, as shown in Figure 12. Loosen the homeowner once installed and adjusted by a qualified position indicator set screw.
  • Page 18: Maintenance And Care

    Figure 14, on page 17. Regularly check to 3. Pull the top of the glass and the frame out and up. insure the area around the Killington is kept free and clear from combustible materials, gasoline, and other 4.
  • Page 19 Contact your authorized dealer for replacement glass. For replacement parts, or for information about parts or service, contact your local HearthStone dealer. For the name of the dealer nearest to you, contact: HearthStone 317 Stafford Ave.
  • Page 20: Parts List

    OWNER’S MANUAL Model # 8870 Killington PARTS LIST Cast Steel cont. Bottom Grill 2810-280 Glass Frame 5870-090 Frame 2810-300 Glass Retainer Clip 5870-092 Left Door 2810-340 Glass Clip 5870-095 Right Door 2810-360 Surround Bracket 5870-100 Top Grill 2810-400 Modesty Panel...
  • Page 21: Troubleshooting

    OWNER’S MANUAL Model # 8870 Killington TROUBLESHOOTING Symptom Possible Cause Corrective Action 1. Pilot will not A. Insufficient gas pressure, air in A. Using the piezo ignitor, try to light the pilot. If it will not light, light. the pilot line, or dirty or kinked gas check the inlet gas pressure.
  • Page 22 OWNER’S MANUAL Model # 8870 Killington Symptom Possible Cause Corrective Action 7. Blue Flames A. A normal result during the first A. Flames should begin to turn more yellowish after 20 minutes of 20 minutes. burning. B. If blue color stays, adjust the air shutter for a proper burn.
  • Page 23: Safety Label

    Jun Jul Oct Nov Dec T his appliance is factory set for use with Natural Gas. A conversion kit for model Killington Direct V ent supplied by HearthS tone shall be used to convert this appliance to the alternate fuel. Instructions will be included with the c onversion kit. Ask for kit# 98-56301 for NG to LP , kit# 98-56300 for LP to NG.
  • Page 24 Purchaser purchases the Stove (the “Purchase Date”). LIMITED LIFETIME WARRANTY HearthStone warrants the following parts of the Stove against the following occurrences that result from defects in material and workmanship: All cast iron parts, including the cast iron heat exchanger – against breakage, cracking or burn-through.
  • Page 25 Dealer, as the case may be, will instruct the Original Purchaser to either return the defective part, or the entire Stove (if needed), with shipping prepaid, to HearthStone or a Dealer or allow a Dealer to make a service call at the place where the Stove is located.
  • Page 26 Stove to and from HearthStone or a Dealer, as the case may be. Notwithstanding any other provision of this document, in no event will HearthStone pay for any Dealer fees or other fees for pick up or delivery of the Stove returned for repair;...