When
BLT REFLECT TEST
a. A color registration adjustment belt reflection test starts (the ONLINE lamp
starts blinking).
b. When the test ends, the upper display shows the result of the test (OK or an
error name), the lower display shows ****RESULT.
Pressing
displays the next test result. Pressing
[2]
result. Pressing
c. Pressing the [#] button during the test cancels the test (turning on the
ONLINE lamp), restoring the state for step 2.
When
BLT REFLECT RSLT
Same button operations as used when BLT REFLECT TEST is executed.
Remark: While the printer is initialized or issues an alarm or the cover is open, it
displays the following message.
4. Repeat steps 2 and 3 when necessary.
5. Press [4] to end the test (the state for step 1 is restored).
Color registration adjustment test items
Display Detail
REG ADJ EXECUTE
REG ADJ RESULT
BLT REFLECT TEST
BLT REFLECT RSLT

2.8.5 Density Adjustment Test

The density adjustment test is used for performing a density adjustment function test and
displaying the result of it to judge whether the density adjustment mechanism is proper.
1. Enter the self-diagnostic-mode and, until the following message appears, press
or [8].
is executed:
restores the state for step 2.
[4]
is executed:
Executes color registration adjustment.
Displays the result of color registration adjustment.
Judges whether color registration adjustment belt reflection is proper or
not
Displays the result of color registration adjustment belt reflection
judgment.
displays the preceding test
[8]
Display Detail
[2]
33