U: Three asterisks (***) identifies a measured upper heater temperature
(in Celsius). Three sharp signs in square brackets ([###]) identifies a target
print temperature (in Celsius).
L: Three asterisks (***) identifies a measured lower heater temperature (in
Celsius). Three sharp signs in square brackets ([###]) identifies a read
lower thermistor AD value (in hex).
T: A measured ambient temperature (in Celsius).
H: A measured ambient humidity (in percent figures).
 The displays are switched by pressing [2].
YTR, MTR, CTR and KTR indicate the set transfer voltage values for
colors, respectively (in kV).
 The displays are switched by pressing [2].
KR: A black transfer roller resistance value (in uA).
YR: A yellow transfer roller resistance value (in uA).
MR: A magenta transfer roller resistance value (in uA).
CR: A cyan transfer roller resistance value (in uA).
 The displays are switched by pressing [2].
ETMP: A parameter for correction of constant hopping motor speed (an
ambient temperature) (in decimal).
UTMP: A parameter for correction of constant fuser motor speed (a target
fusing temperature) (in decimal).
REG: A hopping motor constant-speed timer value (a set input/output
value) (in hex).
EXT: A fuser motor constant-speed timer value (a set input/output value)
(in hex).
 The displays are switched to the following by pressing [2].
ID: An image drum motor constant-speed timer value (a set input/output
value) (in hex).
30