AFE Parameter
Change AFE (IC) register settings
Decimal number displayed, decimal number set.
Maximum values vary with each register.
→ Enter the register [n] setting (n: 1 - 9). The current value is read and displayed
on the panel.
Settings values are changed, configuration and reading conducted, and the results
read are displayed on the panel.
Change AFE (IC) register settings (3 - 9 settings).
Then, read the document using PC Scan.
W: Display message showing that settings are complete.
R: Display read value.
Mechanical Test
ADF Test
Simplex/Duplex
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has been
moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (30 cpm).
Display "Testing" during execution?
→ On the panel, indicate current number of executions using the message "Test
no. xxx underway."
Speed
Color 300 x 300dpi
Color 300 x 600dpi
Color 600 x 600dpi
Mono
Test no. xxx underway
Execute
FBS Test
Speed
Color 300x300dpi
Color 300x600dpi
Color 600x600dpi
Mono
Times
0~65535
Test no. xxx underway
Execute
R3 (03h)
R32 (20h)
R33 (21h)
R34 (22h)
R35 (23h)
R36 (24h)
R37 (25h)
R38 (26h)
R39 (27h)
R40 (28h)
R41 (29h)
R42 (2Ah)
R43 (2Bh)
R38 (26h)