Error Responses

When the XTP T USW 103 receives an SIS command and determines that it is valid, it
performs the command and sends the corresponding response to the host device. If the
command is determined invalid or contains invalid parameters, the switcher returns an error
response to the host. The error response codes are:
= Invalid input number
E01
= Invalid switch attempt in this mode
E06
= Invalid command
E10
= Invalid preset number
E11

Using the Command and Response Table for SIS Commands

The command and response tables begin on page 16. Figure 12 shows the hexadecimal
equivalent of ASCII characters used in the command and response tables.
NOTE: Upper and lowercase text can be used interchangeably unless otherwise stated.
Space
Figure 12.

Symbol Definitions

]
|
}
or
E
W or
ASCII to Hex Conversion Table
ASCII to Hexadecimal Conversion
= Carriage return and line feed
= Carriage return with no line feed
= Space
= Escape key
XTP T USW 103 Switcher • SIS Configuration and Control
= Invalid port number
E12
= Invalid parameter
E13
= Not valid for this configuration
E14
= Invalid command for signal type
E17