TRAY EXIT SENSOR REPLACEMENT
3.2 TRAY EXIT SENSOR REPLACEMENT
1. Remove the bridge unit from the copier. (See the Installation Procedure in the
base copier manual.)
2. Remove the rear cover (2 screws). See Bridge Unit Drive Motor Replacement.
3. Remove the paper tray [A].
4. Remove the exit guide [B] (2 screws).
5. Remove the tray exit sensor [C] (1 connector).
3.3 RELAY SENSOR REPLACEMENT
1. Remove the bridge unit from the copier. (See the Installation Procedure in the
base copier manual.)
2. Stand the bridge unit up as shown in the illustration and remove the sensor [D].
D368
[A]
[B]
8
[C]
B417R104.WMF
B417R102.WMF
[D]