Chapter 3
[1]
2) Remove the power supply shield plate [1].
- 9 screws [2]
[1]

3.5.5.12 Removing the Power Supply Assembly

1) Remove the 3 screws [1]. (The external cover is omitted from the
illustration below to show the instructions clearly.)
2) Remove the four connectors [2] as well as the flat cable [3] on the ECNT
board.
After having removed the flat cable [3], store it inside the unit to protect it
from damage.
[1]
[2]
3) As you remove the bosses on both sides [1], lower the front part of the
power supply assembly [2]. Then pull it to remove the power supply
assembly.
3-36
F-3-228
[1]
[1]
F-3-229
[3]
[2]
[1]
F-3-230
3.5.5.13 Removing the Manual Pickup Solenoid
1) Turn the main unit over so that the front faces down (and the inside is
visible).
2) Remove the cable [1] from the cable guide.
3) Remove the manual feed solenoid [2].
- 1 screw [3]
[3]

3.5.6 Main Motor

3.5.6.1 Removing the Cassette

1) Remove the cassette by holding the cassette handle.
0012-1712
3.5.6.2 Removing the front cover
1) Open the front cover [1] and remove the arm claws [2] to disengage the
connection.
2) Remove the shafts on both sides [3] while warping the shaft arms inside,
and remove the front cover.

3.5.6.3 Removing the right cover

1) Remove the 2 screws [1] on the right cover.
[2]
[1]
F-3-231
[1]
[2]
F-3-232
[3]
[1]
F-3-233
0012-1713
0012-1714
0012-1715
[3]
[2]
0012-1716