3.5.2.8 Removing the Right Frame

1) Remove the right frame [1].
- 3 screws [2]

3.5.2.9 Removing the Plate

1) Remove the plate [1].
- 1 connector [2] on the ECNT board
- 3 screws [3]

3.5.2.10 Removing the Left Frame

1) Remove the left frame [1].
- Remove the cable [2] from the guide.
- 3 screws [3]
[2]

3.5.2.11 Removing the Power Supply Shield Plate

1) Remove the cable from the cable guide.
- 1 connector [1]
[2]
[1]
[2]
F-3-182
[1]
[2]
[3]
F-3-183
[3]
[1]
[3]
F-3-184
0012-1664
[1]
2) Remove the power supply shield plate [1].
- 9 screws [2]
0012-1665
[1]

3.5.2.12 Removing the Power Supply Assembly

1) Remove the 3 screws [1]. (The external cover is omitted from the
illustration below to show the instructions clearly.)
2) Remove the four connectors [2] as well as the flat cable [3] on the ECNT
0012-1666
board.
After having removed the flat cable [3], store it inside the unit to protect it
from damage.
[1]
[2]
0012-1668
3) As you remove the bosses on both sides [1], lower the front part of the
power supply assembly [2]. Then pull it to remove the power supply
assembly.
Chapter 3
F-3-185
[1]
[1]
F-3-186
[3]
[2]
[1]
F-3-187
0012-1670