G. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 12.16.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI fl ame setting, with no adjustment in fl ame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC300AU).
2. If using a wired wall switch with the module in REMOTE
mode, the fl ame output can be adjusted with the HI/LO
selector switch on the module. See Figure 12.16. Note
that the fl ame HI/LO selector switch will become inactive
once an remote control (RC300AU) is programmed to
the control module. Note that the control module will
always ignite the fi replace on HI and remain so for the
initial 10 seconds of operation. If the HI/LO is switched
to the LO position, the fl ame output will automatically
drop to the lowest setting after the fl ame has been
established for 10 seconds. After this 10 second period,
the fl ame can be adjusted from HI to LO with the switch.
3. The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the
RC300AU remote.
4. If you intend to use both an optional wired wall switch
and the RC300AU remote control to operate your
fi replace, the wall switch will override any commands
given by the remote.
5. The module has the capability to recognize potential
malfunctions. If these occur, it will fail to ignite and/
or respond to a command to ignite via the wall switch
and/or remote. In this case, the module may have
gone into LOCK-OUT mode. In this state, it will emit
a LED error code. To reset the error code, switch the
selector to OFF, and then back to REMOTE or ON. If
the ignition command again fails, the module will emit
an LED error code, prior to going back into LOCK-OUT
mode. Contact your dealer for service if this occurs.
Note: If the module is in LOCK-OUT mode, resetting the
circuit breaker to the appliance will also reset the module.
Note: For units installed in Australia, the residence's 220/240
wall outlet to which this appliance's power cord is connected,
must be wired to an in-line on/off switch. This is required for
servicing and/or resetting the control module in the event of
a control module LOCK-OUT.
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
MODULE
WIRE LEAD FROM
REGULATOR CONNECTS HERE
Figure 12.16 Control Module
Hearth & Home Technologies disclaims any responsibility
for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged system component.
• Modifi cation of the system component.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
• Read, understand and follow these instructions for safe
installation and operation.
Fireplace Specifi c Information
Standard fi replace features vary. Consult the installation
manual for available options.
The included AUX300CE receiver provides additional fea-
tures: Fan control and two Aux functions.
The REM300-HNG-AU remote control system functions
include: On/Off, Thermostat Mode, Timer Countdown,
and Flame Adjustment (for fi replaces with variable fl ame).
Kit Contents
REM300-HNG-AU
• REM300-HNG-AU Transmitter
• AAA Batteries (3)
• Wall Holder
• Drywall Anchor (2)
• Screws (2)
Introduction
The RC300AU multifunctional remote control is de-
signed to control pilot light, fl ame height, blower speed,
and up to two 220/240VAC auxiliary functions on your
gas fi replace. The RC300AU is equipped with thermo-
stat functions which can automatically control the tem-
perature in the room in which it is installed. The control
is only for use with the Hearth & Home Technologies
IntelliFire Plus™ system (IPI). The AUX300CE module
is rated for 220/240VAC, 50-60 Hz, and is required for
operation of this remote control device.