K. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, fuel conversion, and in the event that
the control goes into LOCK-OUT mode as a result of an
error code.
ON Position: Appliance will ignite and run continuously
in the HI flame setting, with no adjustment in flame
output. This mode of operation is primarily used for initial
installation and inspection.
REMOTE Position:
Appliance will initiate commands
from a wired wall switch and/or one of the wireless remote
options.
2. A wall switch can be wired into the control module brown
and red wires. See Figure 12.2.
3. The control module has safety feature that automatically
shuts down the fi replace after nine hours of continuous
operation without receiving a command from the wall
switch or optional remote.
4. If you intend to use both a wired wall switch and an optional
remote control to operate your fi replace, the wall switch
will override any commands given by the remote.
MODULE
WIRE LEAD FROM
REGULATOR CONNECTS HERE
Figure 2.3 Control Module
12
SELECTOR
SWITCH
LP/NG GAS-TYPE
SELECTOR SWITCH
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fi replace after nine hours of continuous
operation without receiving a command from the wall
switch or optional remote.