Securing And Leveling The Appliance - Heat & Glo RED40-N-AU Owner's Manual

Table of Contents

Advertisement

B. Securing and Leveling the Appliance
WARNING! Risk of Fire! Prevent contact with:
• Sagging or loose insulation
• Insulation backing or plastic
• Framing and other combustible materials
Block openings into the chase to prevent entry of blown-
in insulation. Make sure insulation and other materials
are secured.
DO NOT notch the framing around the appliance
standoffs. Failure to maintain air space clearance may
cause overheating and fi re.
For details on setting the appliance in the framing, refer
to section 13.B. The diagram shows how to properly po-
sition, level, and secure the appliance (see Figure 9.3 &
9.4). Nailing tabs are provided to secure the appliance to
the framing members.
• Bend out the two nailing tabs on each side.
• Place the appliance into position.
• Keep nailing tabs fl ush with the framing.
• Level the appliance from side to side and front to back.
• Shim the appliance as necessary. It is acceptable to use
wood shims underneath the appliance.
• Secure the appliance to the framing by using nails or
screws through the nailing tabs.
Figure 9.2 shows the fireplace installed on the floor.
However, this fireplace can be elevated off the floor
provided that the fi replace is properly supported by framing
materials and the ceiling clearances are maintained.
NAILING TABS
BOTH SIDES
POSSIBLE LOCATIONS FOR VENT
TERMINATION OF ACTIVE CONVECTION
TECHNOLOGY
Figure 9.2 Proper Positioning, Leveling And Securing Of An Appliance
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
Setting the Fireplace into the Framing
The left and right nailing tabs were designed as a means
to ensure the fi replace is mounted fl ush with the framing
materials.
1. Bend out all 4 nailing tabs.
2. Screw each nailing tab to the adjoining framing mate-
rial. Ensure that the 1 in. (25 mm) air space clearance
is maintained on the sides and back of the fi replace.
See Figure 5.4 and Figure 5.5.
NAILING
TAB
Figure 9.3 Nailing Tabs
Shipping Position
Note: Active Convection Tech-
nology must not pull air from
outside. Termination must draw
TERMINATION INTO INTERIOR ROOM
NAILING
TAB
Figure 9.4 Nailing Tabs
Installation Position
air from an interior room.
6 in. (152 mm) X 5.5 in. (140 mm)
REQUIRED
GRILLE PANEL
DUCT COLLAR
ASSEMBLY
35