Active Convection Blower Replacement - Heat & Glo RED40-N-AU Owner's Manual

Table of Contents

Advertisement

F. Active Convection Blower Replacement
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
1. Remove any interior enhancement kit(s), such as
glass rock media or porcelain, that have been already
installed in the appliance.
2. Remove pilot shield as shown in Figure 12.3.
Figure 12.3 Removing Pilot Shield
3. Remove screws from base pan and lift base pan up
and out of appliance. Set aside. See Figure 12.4 and
Figure 12.5.
Figure 12.4 Removing Screws from Base Pan
Figure 12.5 Lifting Base Pan Up and Out
48
Heat & Glo • RED40-N-AU, RED40ST-N-AU • 2294-900 Rev. G • 7/14
4. Remove screws from each end of burner assembly.
Remove 2 screws retaining pilot assembly to burner
assembly. Move pilot assembly enough for burner
assembly to be tilted and disengaged off of orfi ce neck.
Set burner assembly aside.
Figure 12.6 Side Burner Screw
5. Remove left or right side glass pane frame, depending
on placement of blower, from bottom of fi rebox. Remove
glass pane and gaskets. Gaskets may have become
fragile from heat exposure. Handle with care. At this
point, blower and other components located under the
fi rebox are accessible.
Figure 12.7 Glass Pane Frame
Figure 12.8 Removing Glass Pane Frame
6. Locate the fan mount fastener on either the left or
right side of the appliance. See Figure 12.9. Remove
fastener.
SIDE BURNER SCREW