Default (Factory); Installer Lockout; Walk Test (Installer) - DSC PC5015 Installation Manual

Hide thumbs Also See for PC5015:
Table of Contents

Advertisement

P
R
O
G
feature can be enabled separately for telephone numbers 1/3 and 2.
All talk/listen and/or video sessions will be disconnected if the panel needs to communicate alarms to
the central station.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Phone 1 & 3 Listen-In Enabled .............................. Section [381], Option 5
Phone 2 Listen-In Enabled ..................................... Section [381], Option 6
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.27.2
Periodic Camera Test
When the Periodic Camera Test option is enabled, the panel will test cameras connected to a PC5108L
module every 30 minutes. Only cameras with the Camera Test option enabled will be tested. See your
PC5108L Installation Manual for more information on camera tests.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Periodic Camera Test ............................................. Section [017], Option [7]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.28

Default (Factory)

On occasion it may be necessary to default the main control panel or one of the modules that can be
connected. There are several different defaults available including defaulting the main control panel,
Escort5580 module, PC5132 Wireless Expander Module, PC5400 Printer module and an Alternate
Communicator.
Note: Defaulting the main panel does not default the keypads. Please refer to "Programming
LCD5500Z Keypads" in the Programming Worksheets for defaulting the LCD5500Z. PC55XXZ LED
keypads must be manually reprogrammed in installers section [000].
5.28.1
Factory Default Main Panel (Hardware)
Step 1 - Remove AC and battery from the panel.
Step 2 - Remove all wires from the Zone 1 and PGM1 terminals.
Step 3 - With a piece of wire short the Zone 1 terminal to the PGM1 terminal.
Step 4 - Apply AC power to the main panel.
Step 5 - When Zone Light 1 is lit on the keypad the default is complete.
Step 6 - Remove AC power from the control
Step 7 - Reconnect all original wiring and power up the control.
AC power must be used to power the panel. The panel will not default if the battery is used.
5.28.2
Factory Default Main Panel (Software) and other Modules
Step 1 - Enter Installer Programming.
Step 2 - Enter Program Section [99X].
Step 3 - Enter the Installer Code.
Step 4 - Enter Program Section [99X] again.
The panel will take a few seconds to reset. When the keypad is operational, the default is complete.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Restore Alternate Communicator to Factory Default Programming ... Section [993]
Restore Escort5580 to Factory Default Programming ......................... Section [995]
Restore PC5132 to Factory Default Programming .............................. Section [996]
Restore PC5400 to Factory Default Programming .............................. Section [997]
Restore PC5928 to Factory Default Programming .............................. Section [998]
Restore Main Panel (Software) to Factory Default Programming ....... Section [999]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.29

Installer Lockout

If Installer Lockout is selected a hardware default cannot be performed. If a software default is
performed all programming will restore to factory default.
When Installer Lockout Disable is selected the panel will restore all programming to factory defaults if a
hardware or software default is performed on the main control panel.
To enable or disable Installer Lockout perform the following:
Step 1 - Enter Installer Programming.
Step 2 - Enter Program Section [99X].
Step 3 - Enter the Installer Code.
Step 4 - Enter Program Section [99X] again.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Installer Lockout Enable ......................................... Section [990]
Installer Lockout Disable ........................................ Section [991]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.30

Walk Test (Installer)

The Installer Walk Test can be used to test the alarm state of each zone of the panel. The walk test
cannot be used to test zone type [24].
Before beginning the walk test, ensure the following conditions are met:
1. The panel is disarmed
2. The Keypad Blanking option is disabled (section [016]: [3])
3. The Fire Bell is Continuous option is disabled (section [014]: [8])
4. The Transmission Delay is disabled, if Transmission Delay is not required (section [370])
Fire Troubles are not supported in Walk Test.
All outputs will activate for both partitions during the walk test, regardless of programming.
R
A
M
D
E
S
C
R
I
39
P
T
I
O
N
S