P
R
O
G
is enabled, the programmed Time of Day Timer [371] will not apply.
Test Transmission Interval in Days: A test transmission will be sent to the monitoring station at the
programmed time of day in Section [371] and at the Interval programmed in Section [370].
4. 1600Hz/Standard Handshake: With this option enabled the communicator will respond to 1600Hz
handshakes when using the reporting Communication Formats 1 and 2 only. The Standard Handshake
is 1400Hz or 2300Hz.
5. ID Tone Enabled: With ID Tone Enabled the panel will pulse a tone on the telephone line to indicate
that the panel is on the line.
6. 2100Hz/1300Hz: Selectes the frequency of the ID tone that is pulsed on the line. Contact your local
telephone company to confirm which setting should be used.
7. One Time 1-Hr User enabled DLS Window: When the User enables the DLS Window through [ ][6][Master
Code][5] the panel will answer an incoming call for Downloading within the 1-Hr time Window without having
to have Downloading Answer Enabled in Section [401]. After a successful Download has been completed
the Window will be closed and a call will not be answered unless Downloading Answer is Enabled.
Full 6-Hr User enabled DLS Window: When the User enables the DLS Window through [ ][6][Master
Code][5] the panel will answer an incoming call for Downloading within the 6-Hr window. The window
will remain open for the full 6 hours.
8. Bell on FTC when Armed: When enabled, an FTC (Failure to Communicate) on either Partition during the
armed period will sound an Audible Alarm for the length of Bell time-out or until the system is disarmed.
FTC Trouble only when Armed: If a Failure to Communicate trouble is generated while the panel is
armed only the keypad buzzer will sound trouble beeps every 10 seconds until a key is pressed.
5.31.4
[703] Delay Between Dialing Attempts
The Delay Between Dialing Attempts timer adds a delay before the next call is dialed (after step d in the
Force Dialing section, or after a busy tone is detected in the Busy Tone Detection section).