• BAD signal will be indicated by Light 3 on an LED keypad
or the word BAD on an LCD keypad. It will be enunciated
on the Keypad by 3 beep and on the Bell by 3 Squawk.
• Non-Enrolled zone will be annunciated on the Keypad by
an error tone.

[906] - For Future Use

[989][Installer Code] - Default Master Code

This will allow the installer to default the Master Code to the fac-
tory defaults.

[990][Installer Code] - Installer Lockout Enable

If enabled, the panel will give a distinctive audible indication on
power up (the phone line relay will click 10 times). This feature will
have no effect on a Software Default (all programming will return
to the factory defaults). However, if a hardware default is
attempted while lockout is enabled, the default will not occur, and
the fraudulent attempt will be logged to the event buffer.
Installer Lockout
If Installer Lockout is selected a hardware default cannot be per-
formed. If a software default is performed all programming will
restore to factory default.
When Installer Lockout Disable is selected the panel will restore
all programming to factory defaults if a hardware or software
default is performed on the main control panel.
To enable Installer Lockout perform the following:
1. Enter Installer Programming.
2. To enable Installer Lockout, enter section [990]
3. Enter the Installer Code.
4. Enter section [990] again.

[991][Installer Code] - Installer Lockout Disable

This disables the Installer Lockout feature described above.
To disable Installer Lockout perform the following:
1. Enter Installer Programming.
2. To disable Installer Lockout, enter section [991].
3. Enter the Installer Code.
4. Enter section [991] again.

[993]-[999] - Factory Defaults

On occasion it may be necessary to default the main control panel
or one of the modules that can be connected. There are several
different defaults available including defaulting the main control
panel, Escort5580(TC) module, PC5132 Wireless Expander Mod-
ule, PC5400 Printer module.
NOTE:
Defaulting the main panel does not default the keypads.
Refer to the Programming Worksheets Appendices A and B for
instructions for defaulting keypads. Keypads must be manually
reprogrammed in programming section [000].
Factory Default Main Panel (Hardware)
1. Remove AC and battery from the panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire short the Zone 1 terminal to the PGM1
terminal.
4. Apply AC power to the main panel.
5. When Zone Light 1 is lit on the keypad the default is com-
plete.
6. Remove AC power from the control
7. Reconnect all original wiring and power up the control.
NOTE:
AC power must be used to power the panel. The panel will
not default if the battery is used.
Factory Default Main Panel (Software) and other
Modules
1. Enter Installer Programming.
2. Enter the appropriate programming section [99X].
3. Enter the Installer Code.
4. Enter the appropriate programming section [99X] again.
The panel will take a few seconds to reset. When the keypad is
operational, the default is complete.
[993][Installer Code] - Restore Alternate Comm. Factory
Default Programming
When this section is successfully entered, all programming in the
Alternate Communicator will be returned to the factory defaults.
[995][Installer Code] - Restore ESCORT5580(TC) Factory
Default Programming
When this section is successfully entered, all programming in the
ESCORT5580(TC) Module will be returned to the factory defaults.
[996][Installer Code] - Restore PC5132 Wireless Factory
Default Programming
When this section is successfully entered, all programming in the
PC5132 Wireless Expansion Module will be returned to the fac-
tory defaults.
[997][Installer Code] - Restore PC5400 Factory Default Pro-
gramming
When this section is successfully entered, all programming in the
PC5400 Serial Module will be returned to the factory defaults.
[998][Installer Code] - Restore PC59XX Factory Default Pro-
gramming
When this section is successfully entered, all programming in the
PC59XX Audio Interface Module will be returned to the factory
defaults.
[999][Installer Code] - Restore Factory Default Programming
When this section is successfully entered, all programming in the
PC1616/PC1832/PC1864 will be returned to the factory defaults.
The programming for the ESCORT(TC), PC5132, PC5400 and
PC59XX modules will not be defaulted. When this command is
executed, the Module Supervision Field will be reset.
49