Fire alarms have precedence over burglary alarms. If two different PGM Outputs are used to activate
alarms, one for Partition 1 and one for Partition 2, silent alarms will be audible if the either Partition is
in an audible alarm condition.
[02] For future use
[03] Sensor Reset ([ ] [7] [2])
This output will normally be active (switched to ground).
This option is used to reset power for latching smoke detectors. The output will deactivate for five
seconds when the [ ] [7] [2] command is entered (see Section 3.4 "[ ] [7] Output Functions"). The
keypad buzzer will not sound for the five second period.
Please refer to the Control Panel Wiring Diagram in this manual for wiring instructions.
Only ONE of options [03] Sensor Reset and [20] [ ] [7] [2] Command Output Option #2 may be
programmed on the same system.
[04] For future use
[05] Partition/System Armed Status The output will activate when the Partition or System is armed and
deactivate when disarmed.
[06] Ready Output The output will activate when the Partition or System is ready to arm. The output will
deactivate when the system is not secure or upon arming.
[07] Keypad Buzzer Follow The output will activate when any of the following events occur and will
remain active for as long as the keypad buzzer is active:
• Door Chime
• Auto-Arm Prealert
[08] Courtesy Pulse Upon arming the output will activate for the duration of the exit delay plus two
minutes. Upon entry the PGM output will activate for the duration of the entry delay plus two minutes. If
more than one courtesy pulse output is required, they all must be programmed for global operation (PGM
attributes 1 and 2 enabled).
[09] System Trouble Output The output will activate when any of the selected trouble conditions are
present. It will deactivate when all the selected trouble conditions are cleared.
The PGM attributes for this option, programmed in Sections [141] to [142], differ from the standard
selection of attributes. Program which trouble conditions will activate the output by selecting some or all
of the following attributes:
[1] .. Service Required
(battery, bell, general trouble,
general tamper, general supervisory)
[2] .. AC Failure
[10] Latched System Event (Strobe Output) The output will activate when any of the selected system events
(alarms) occur on the system. In the armed state, the output will deactivate only once the system is disarmed.
If an alarm activates this output in the disarmed state, the output will deactivate if a user enters a valid
access code while the Bell Cut-off timer is counting down. The output will also deactivate if someone
arms the system after the Bell Cut-off has expired. This output can be used to indicate that an alarm has
occurred before entering the premises.
The PGM attributes for this option, programmed in Sections [141] to [154], differ from the standard selection of
attributes. Program which events will activate the output by selecting some or all of the following attributes:
[1] ...... Burglary (Delay, Instant, Interior, Stay/Away and 24 Hour Burglary Zones)
[2] ...... Fire (Fire Keys, Fire Zones)
[3] ...... Panic (Panic Keys and Panic Zones)
[4] ...... Medical (Auxiliary Keys, Medical and Emergency Zones)
[5] ...... Supervisory (Supervisory, Freezer and Water Zones)
[6] ...... Priority (Gas, Heat, Sprinkler and 24 Hour Latching Zones)
[7] ...... Holdup (Holdup zones)
[8] ...... Output follows pulse timer (Section [164])
This output will activate for silent and audible alarms or medical conditions only. It will not activate
during pre-alert or delays.
[11] System Tamper The output will activate when any Tamper condition is present and will deactivate
when all Tamper conditions are cleared.
[12] TLM and Alarm The output will activate when a telephone line fault condition is present AND an
alarm occurs. The output will remain active until an access code is entered. The output will activate for
both audible and silent alarms if a TLM trouble is present.
This output will activate for all audible and silent alarms except Duress.
A
M
D
E
• Entry Delay
• 24 Hour Supervisory Buzzer Zone
[3] .. Telephone Line Trouble
[4] .. Failure to Communicate
[5] .. Fire Trouble / Zone Fault
31
S
C
R
I
P
• Audible Exit Delay
[6] .. Zone Tamper
[7] .. Zone Low Battery
[8] .. Loss of Clock
T
I
O
N
S