Downloading Telephone Number; Downloading Access Code; Panel Identification Code; For Future Use - DSC PC-LINK9 Installation Manual

Hide thumbs Also See for PC-LINK9:
Table of Contents

Advertisement

[26] Downloading Telephone Number

This telephone number is used by the panel to call the
downloading computer when a request to call is make by
entering [
][4] or for an auto-download. See Section [14]
3rd System Option Code, lights 2 and 3. See Section [01] 1st
Phone Number for instructions on programming the
downloading telephone number.
[27]

Downloading Access Code

This 4-digit code allows the panel to confirm that it is
communicating with a valid downloading computer. Enter 4
digits using the numbers 0 through 9 only. The factory default
code is [1515].
[28]

Panel Identification Code

This 4-digit code allows the downloading computer to confirm
the identity of the control panel. Enter 4 digits using the
number keys 0 through 9 only. The factory default code is
[1501].
[29]

For Future Use

[30]

Reset to Factory Default

Software
Entering [30] will perform a software reset to the factory default
values. Once this command is entered, the keypad buzzer will
beep several times. The "Trouble" LED will be ON during the
reset sequence.
Hardware
If the installer's code is forgotten and a software reset cannot
be performed, the panel can be reset to the factory default
values with the following method.
1. Remove all power, AC and battery, from the panel.
2. Short the pads on the panel labelled EEPROM RESET.
3. While maintaining the short, power-up the panel and
wait for at least 10 seconds before removing the short.
4. Upon removal of the short, the keypad buzzer will beep
and the panel will be reset to the factory default values.
[31]

4th System Option Code

Use the same programming method as in Section [12].
ZONE
LIGHT
[1]
• OFF = For future use
• OFF = For future use
[2]
[3]
• OFF = For future use
[4]
ON = Show bypass status while armed or disarmed
• OFF = Show bypass status while disarmed only
[5]
ON = Set for AC = 50 Hz
• OFF = Set for AC = 60 Hz
[6]
ON = Restore on bell time-out (if zone is restored)
• OFF = Restore as follower (when zone restores)
• Factory default
[32] 5th System Option Code
Use the same programming method as in Section [12].
ZONE
LIGHT
[1]
ON = Loss of AC will not cause an AC trouble
• OFF = Loss of AC will cause AC trouble
[2]
ON = No bell during Auto-Arm (burst every 10
seconds is silenced)
• OFF = 1 burst of bell / siren every 10 seconds
during Auto-Arm pre-alert
[3]
• ON = Home-Away zones will have an entry
delay when tripped
OFF = Home-Away zones act as interior when
tripped
[4]
ON = Quick-Exit is enabled ([
1 transition of a delay zone)
• OFF = Quick-Exit is disabled
[5]
ON = Auxiliary delay zones can be force armed
• OFF = Auxiliary delay zones cannot be force
armed
[6]
• ON = All zones except fire will be bypassed for
60 seconds upon power-up
OFF = All zones are active upon power-up
• Factory default
[33] For Future Use
[34] 6th System Option Code
Use the same programming method as in Section [12].
ZONE
LIGHT
[1]
ON = Audible Exit Delay with urgency
• OFF = Standard Exit Delay
[2]
ON = Bell Squawk during Exit Delay
• OFF = No Bell Squawk during Exit Delay
[3]
ON = Audible Exit Fault enabled
• OFF = Audible Exit Fault disabled
[4]
ON = Urgency applied to Entry Delay
• OFF = Standard Entry Delay
[5]
ON = Bell Squawk during Entry Delay
• OFF = No Bell Squawk during Entry Delay
[6]
ON = [F] Key disabled
• OFF = [F] Key enabled
• Factory default
When Light 3 is ON (Audible Exit Fault):
system is armed and a Standard Delay Zone is left open
at the end of the Exit Delay, the bell/siren will sound a
steady tone for the duration of the Entry Delay.
Entry and Exit Delay Urgency:
option is selected for the audible Entry Delay, the keypad
will sound a constant tone during the Entry Delay. During
the last 10 seconds of the Entry Delay, the keypad will
sound a pulsing tone to warn that the delay is about to
expire.
When the urgency option is selected for the audibile Exit
Delay, the keypad will sound a pulsing tone during the Exit
Delay. During the last 10 seconds of the Exit Delay, the
keypad will sound a faster pulsing tone to warn that the delay
is about to expire.
][0] ignores
When the
When the urgency
17