Call Direction Options for the event. In addition the Call
LINKS1000/GSM1000 as well as Land Line option must be
selected.
The panel will call the LINKS1000/GSM1000 and then call the
land line when reporting the selected event.
LINKS1000/GSM1000 Special Preamble
In some areas of North America, dialing #DAT or *DATA reduces
the cellular billing increment. The LINKS1000/GSM1000 Special
Preamble (section [393]), allows the use of [*] and [#] characters
for the programming of #DAT and *DATA.
The LINKS1000/GSM1000 Special Preamble is sent BEFORE the
Preamble programmed in Sections [390] to [392].
Example: [Special Preamble][Regular Preamble][Telephone Num-
ber]
NOTE: If this Special Preamble is programmed, it will be
inserted before the Regular Preamble of ALL telephone
numbers. Hex digits D and E are not supported for Pream-
ble programming.
If Busy Tone Detection is enabled, the LINKS1000/GSM1000
must be tested to ensure full operation.
Please refer to the LINKS1000/GSM1000 Installation Manual for
more information and connection diagrams.
LINKS1000/GSM1000 Preamble
(First Telephone Number). . . . . . . . . . . . . . . . . . . .Section [390]
LINKS1000/GSM1000 Preamble
(Second Telephone Number) . . . . . . . . . . . . . . . . .Section [391]
LINKS1000/GSM1000 Preamble
(Third Telephone Number) . . . . . . . . . . . . . . . . . . .Section [392]
LINKS1000/GSM1000 Preamble
(All Telephone Number). . . . . . . . . . . . . . . . . . . . .Section [393]
LINKS1000 Preamble
(Downloading Telephone Number) . . . . . . . . . . . .Section [490]
Communicator Call Direction Options . . . Section [351] to [376]
Call LINKS1000/GSM1000 as well as
Land Line . . . . . . . . . . . . . . . . . . . . . . Section [380], Option [7]
Maximum Dialing Attempts . . . . . . . . . . . . . . . . .Section [165]

5.27 Module Programming

The programming sections listed below pertain to additional
modules on the system. For instructions on programming these
modules and a description of each programming section, see
their respective installation manuals.
PC5400 Programming. . . . . . . . . . . . . . . . . . . . . .Section [801]
PC5928 Programming. . . . . . . . . . . . . . . . . . . . . .Section [802]
Alternate Communicator Programming. . . . . . . . .Section [803]
PC5132 Programming. . . . . . . . . . . . . . . . . . . . . .Section [804]
PC5100 Programming. . . . . . . . . . . . . . . . . . . . . .Section [805]
PC5108L Programming . . . . . . . . . . . . . . . . . . . . .Section [806]
PC5928 Audio Interface Module
The PC5928 Audio Interface will allow you to connect up to 7
Interior (PC5921) or exterior (PC5921EXT) Intercom Stations.
These attractive, surface mount stations contain both speaker
and microphone and will allow you to add intercom features to
your alarm system such as:
• Page/Answer
• Do Not Disturb
• Baby Monitor
34
• Answer Incoming Calls
• Doorbell Function
• Background Music
In addition to these features the module also has the Listen-in
feature for central station monitoring. The central station can
select the audio station, listen/talk, extend on-line time and hang
up. The Listen-In feature can be enabled separately for telephone
numbers 1/3 and 2.
NOTE: All talk/listen and/or video sessions will be discon-
nected if the panel needs to communicate alarms to the
central station.
Telephone 1 & 3 Listen-In Enabled . . . . Section [381], Option 5
Telephone 2 Listen-In Enabled. . . . . . . . Section [381], Option 6
Periodic Camera Test
When the Periodic Camera Test option is enabled, the panel
will test cameras connected to a PC5108L module every 30 min-
utes. Only cameras with the Camera Test option enabled will be
tested. See your PC5108L Installation Manual for more informa-
tion on camera tests.
If the Local Mode option is turned on, the panel will always
send events to the PC5108L Module, and Downlook will not be
initiated if requested. If the Local Mode option is turned off, the
panel will only send communicated events to the PC5108L Mod-
ule. Downlook will be initiated when requested. Please see your
PC5108L Installation Manual for more information.
Periodic Camera Test . . . . . . . . . . . . . Section [017], Option [7]
Local Mode Enabled/Disabled . . . . . . . Section [381], Option [8]

5.28 Factory Default

On occasion it may be necessary to default the main control
panel or one of the modules that can be connected. There are
several different defaults available including defaulting the main
control panel, Escort5580 module, PC5132 Wireless Expander
Module, PC5400 Printer module and LINKS2X50 module.
NOTE: Defaulting the main panel does not default the key-
pads. Please refer to the Programming Worksheets Appen-
dices A and B for instructions for defaulting LCD5500Z and
LCD5501Z keypads. PC55XXZ LED keypads must be manu-
ally reprogrammed in programming section [000].
Factory Default Main Panel (Hardware)
1. Remove AC and battery from the panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire short the Zone 1 terminal to the PGM1
terminal.
4. Apply AC power to the main panel.
5. When Zone Light 1 is lit on the keypad the default is com-
plete.
6. Remove AC power from the control
7. Reconnect all original wiring and power up the control.
NOTE: AC power must be used to power the panel. The
panel will not default if the battery is used.
Factory Default Main Panel (Software) and other
Modules
1. Enter Installer Programming.
2. Enter the appropriate programming section [99X].