Keypad Lockout; Keypad Blanking; Loop Response; Keypad Tampers - DSC PC5015 Installation Manual

Hide thumbs Also See for PC5015:
Table of Contents

Advertisement

P
R
O
G
Late to Close
If the Late to Close option is enabled, the panel will transmit the Late to Close reporting code whenever
the auto-arm pre-alert sounds. If there is an auto-arm time programmed for that day, the panel will
transmit the reporting code whether or not auto-arming is enabled (in the [ ][6][2] menu). The Late to
Close reporting code must also be programmed for this feature to function.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Program Time and Date ......................................................................... [ ][6][1]
Enable Auto Arming ................................................................................ [ ][6][2]
Enable Auto Arm Day ............................................................................. [ ][6][3]
Auto Arm Times .................................................................. Sections [180]-[193]
Auto Arm Postpone Reporting Code ............................................ Section [348]
Partial Closing Reporting Code .................................................... Section [343]
Late to Close Enable/Disable ...................................... Section [017], option [5]
Late to Close reporting code ......................................................... Section [343]
Partition 1 or 2 Auto-arm Schedule in [ ][6] .... Section [017], options [2] & [3]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.22

Keypad Lockout

The panel can be programmed to 'lockout' keypads if a series of incorrect access code entries are made.
After the Number of Invalid Codes Before Lockout has been reached the panel will lock out the keypad
for the Lockout Duration and log the event to the event buffer. For the duration of the lockout the panel
will sound an error tone when any key is pressed. The invalid code counter will be reset every hour.
To disable Keypad Lockout program the Number of Invalid Codes Before Lockout as [000].
If Keypad Lockout is active, the panel cannot be armed / disarmed with a keyswitch.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Number of Invalid Codes Before Lockout .............. Section [012]
Lockout Duration ..................................................... Section [012]
Keypad Lockout Reporting Code ........................... Section [338]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.23

Keypad Blanking

If the Keypad Blanking Option is enabled the panel will turn off all lights and LCDs on the keypads if no
key is pressed for 30 seconds. The keys, however, will remain backlit.
The panel will turn the lights and LCDs back on if entry delay begins or an audible alarm occurs. The
lights and LCDs will also come on if a key is pressed or, if the Code Required to Restore Blanking
Option is enabled, a valid access code is entered.
If the Power Save Option is enabled the panel will blank all keypad lights including backlighting when
AC power fails, in order to conserve the back up battery.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Blanking Option ......................................... Section [016], Option [3]
Code Required to Restore Blanking ...................... Section [016], Option [4]
Power Save Option ................................................. Section [016], Option [6]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.24

Loop Response

The normal loop response time for all zones is 500 milliseconds. The panel will not consider a zone
violated unless it is violated for at least 500 milliseconds.
If Zone 1 is Fast Loop Response is enabled the loop response for zone 1 will be 40 milliseconds.
Typically this can be used for vibration type sensors.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Zone 1 is Fast Loop Response .............................. Section [013], Option [5]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.25

Keypad Tampers

If the Keypad Tampers Enable option is selected the panel will display and transmit a General System
Tamper reporting code if any keypad is removed from the wall. When the keypad tamper is restored the
panel will transmit the General System Tamper Restoral reporting code. All keypads should be properly
installed and secured before enabling this option.
By enabling Tampers/Faults Do Not Show as Open, faults and tampers for keypad zones will not show
as open on the keypad, and will be hidden from the end user. If the option is disabled, faults and tampers
will show as open.
Entering and exiting Installer's Programming will not reset the system tampers. All tamper conditions
must also be physically restored.
Once a zone is tampered or faulted, it must be completely restored before the trouble condition will clear.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Tamper Enable ......................................................... Section [016], Option [8]
General System Tamper Reporting Code ............................ Section [338]
General System Tamper Restoral Reporting Code ............. Section [338]