Assembly And Preparation - aoyue INT 738 Instruction Manual

Professional repairing system
Table of Contents

Advertisement

OPERATING PROCEDURE 
E.. SMOKE ABSORBER 
1.  Wait   until   the   soldering   iron   reaches   the   set  temperature   and 
stabilizes. 
2.  Set Vacuum Control to
 smoke absorber
3.  Check if the Vacuum Indicator lights up. 
4.  Fumes absorbed will pass through a filter and be blown out thru the 
hot  air  gun.  So  the  smoke  that  is  blown  out  from  the  hot  air  gun 
during soldering is already filtered. 
IMPORTANT:   Filters   should   be   cleaned   and   replaced 
regularly so  that  it  would  not  clog  up  the  air  path  and  will 
effectively clean the toxic fumes produced during soldering 
process. 
CARE and MAINTENANCE 
A.  Replacing the Hot Air Gun heating element 
1.  Remove  the  screws  which  secure  the  handle  and  slide  the  cord 
tube. 
2.  Open  the  handle.    Disconnect  the  ground  wire  and  remove  the 
pipe. 
3.  Remove the heating element by disconnecting the terminal. 
4.  Insert a new heating element and reconnect the terminal. Handle 
the     heating element with care.  Never rub its wire.  Reconnect 
the ground wire after replacing the element. 
5.  Assemble the handle in the reverse order of disassembly. 
B.  Care for the Soldering Iron tip. 
Always  keep  the solder­plated section  of  the  tip  coated  with  a small 
amount of solder. If the tip is coated with oxide, the tip's heat conductivity 
will  be  lowered.  Coating  the  tip  with  a  small  amount  of  fresh  solder 
ensures maximum heat conductivity. 
16 
ASSEMBLY and PREPARATION
A.  Soldering Iron 
1. Install the solder wire to the soldering iron holder as in Figure 2. 
Figure 2. Soldering iron stand with solder wire holder 
2.   Connect   the   soldering   iron   cord   assembly   to   the   5­pin   output 
terminal found at the lower portion of the main unit. Please refer to 
item 8 from the Control Panel Guide. 
3. Place soldering iron to the soldering iron stand as shown above. 
B. Hot Air Gun 
The Hot Air Gun holder was installed on the station upside down 
for packaging purpose. To set up the Hot Air Gun holder: 
1.  Loosen the two screws that secure the holder to the station. 
2.  Turn the holder right upside. 
3.  Fasten the two screws back. 
4.  Place the hot air gun on the holder in preparation for usage. 
Note: Make sure the screw at the center of the base of the main unit 
has been removed. This holds the pump in place during transportation 
and needs to be removed before using the equipment. 
C. Smoke Absorber 
Attach the smoke absorbing tube to the vacuum cap. Make sure that 
the cord connections are free from any tangles. 