OPERATING GUIDELINES 
6. 
You may start reworking as soon as the desired air temperature and 
air pressure levels are reached. 
7. 
.  When  reworking  is  complete,  place  the  Hot  Air  Gun  back  to  its 
holder. 
8. 
Deactivate the HOT AIR GUN function switch (15). The system will 
immediately start the auto­cooling process. 
Note: During this process, the system will try to release excess heat by 
blowing air (at room temperature) until it reaches a safe  temperature 
value of 85°C before completely switching OFF. 
Wait for the auto­cooling process to finish before switching OFF the 
9. 
main  power  switch  (9).  If  the  display  panel  shows  "OFF"  on  each 
line, then it is now safe to do so. 
10. 
Unplug the device from the main power source. 
IMPORTANT: Remember to set airflow level first before setting the 
temperature so that it would not damage the heating element, causing it to be 
burnt out prematurely. This would help lengthen the usage life span of 
main unit and the heating element. 
IMPORTANT: Airflow level should be set accordingly, working with low 
airflow and high temperature often causes heating element to get easily burnt. 
12 
OPERATING GUIDELINES 
Auto­cool off function 
1. 
When  reworking  is  complete,  return  the  Hot  Air  Gun  to  its  holder 
and  DO  NOT  immediately unplug the device from the main power 
source. 
2. 
Deactivate  the  HOT  AIR  GUN  activation  switch  first  in  order  to 
activate the auto­cooling process. The system will start to blow air 
(at  room  temperature)  at  maximum  rate  to  reduce  heat  from  the 
hot air gun and bring the temperature down to a safe level of 90°C. 
During  this  time,  the  prefix  of  hot air  gun  temperature  display  will 
also   change   from   "H"   to   "C"   while   temperature   is   gradually 
decreasing.  The  air  pressure  level,  likewise,  will  be  at  its  highest 
reading as indicated from the display panel. Once the temperature 
drops to approximately 90°C  the hot air gun will automatically stop 
and display "OFF" on the panel. It is now safe to unplug the device 
from the main power source if the system reached this stage. 
the 
3. 
Unplug the device from the main power source. 
4. 
Allow  the  device  (and  its  components)  to  completely  cool  down 
before   keeping   in   a   safe   and   dry   place.   (Optional   but 
recommended).