PACKAGE INCLUSION
BASIC TROUBLESHOOTING GUIDE
PROBLEM 1: THE UNIT HAS NO POWER
1. Check if the unit is switched ON.
738 Main Station
2. Check the fuse. Replace with the same type if fuse is blown.
3. Check the power cord and make sure there are no disconnections.
4. Verify that the unit is properly connected to the power source.
Air Nozzles
o
PROBLEM 2: TEMPERATURE DISPLAY IS ALWAYS ABOVE 500
C
(1124, 1130,
o
Description: Constant display of above 500
C temperature from the
1197,1010, 1313,
panel then displays a blinking "OFF" on the panel after a few minutes.
Hot Air Gun and
SOLUTION:
Hot Air Gun Holder
Soldering Iron with
The thermal sensor may be broken and needs to be replaced.
Smoke Absorber
PROBLEM 3: ACTUAL AIR TEMPERATURE IS NOT INCREASING
Description: Actual temperature reading is not increasing or decreasing
based on desired level. The panel will then display a blinking "OFF" on
2630B Soldering Iron Holder
panel.
939 Vacuum
with Solder Wire Stand
Suction Pen
SOLUTION:
The heating element may be broken and needs to be replaced.
PROBLEM 4: THE UNIT IS VIBRATING TOO MUCH
Check if the 4 screws that hold the pump in place are properly and tightly
Power Cord
G001 IC Popper
connected. Unplug the system from the main power source before
opening the case to check the internal settings.
PROBLEM 5: THE UNIT IS VERY NOISY
Soldering Iron
30181X Filter Pads
SOLUTION: Make sure the screw at the center of the base of the main
Spare Heating Element
(6 pcs.)
unit has been removed. This holds the pump in place during
transportation and needs to be removed before using the equipment.