OPERATING GUIDELINES 
IMPORTANT REMINDERS: 
1.  Make sure the equipment is placed on a flat stable surface and 
all  its  heat­generating  components  placed  on  their  respective 
holders/stands. 
2.  Ensure all switches are OFF prior to reworking. 
3.  Ensure all terminal connections are properly secured. 
NOTE: Please refer to the CONTROL PANEL GUIDE if needed. 
A. START­UP PROCEDURE 
1.  Plug the device to the main power source. 
2.  Switch ON the device using the main power switch (item 9 on the 
CONTROL PANEL GUIDE) found at the lower right portion of the 
control panel. 
3.  The display panel will show the product name momentarily and then 
"OFF" on each line of the panel, provided all function switches are 
deactivated. See below for illustration. 
4.  The air gauge (item 1) will also appear illuminated by ample light and 
the metal ball inside is at the lowest position of the visible area. 
5.  The system will remain in this state until a function is activated. 
10 
OPERATING GUIDELINES
C.   AUTOMATE HOT AIR REWORKING 
1. 
Turn on the hot air gun function switch , and set to the desired 
reworking temperature. Turn of hot air gun function switch. 
2. 
Turn on the automate function switch,"16" from the panel, Set the 
time by using the  up/down rework time button,"4" from the panel. 
It is preset at 300 seconds. 
3. 
After preferred automate rework time has been set. Turn on the hot 
air gun function switch. 
4. 
Timer would start counting down when the actual hot air 
temperature has reached the set temperature. Once automate 
rework time is finished, it would cool down automatically, and 
display the letters "End" indicating automate process is finished. 
5. 
To resume manual hot air reworking de­press automate function 
switch. 
D.  SOLDERING IRON 
1. 
Check if the Soldering Iron is attached properly to the 6­pin 
receptacle and the vacuum tube is securely connected. 
2. 
Turn on the Power Switch. 
3. 
Press the Soldering Iron  function switch to turn on soldering iron. 
"18" from  the panel. 
4. 
When the display shows the word "PLUG" check the connection of 
the soldering iron to its receptacle. 
5. 
The Solder iron is set to automatically increase temperature to 249° 
C upon turning on. It will show the set temperature when you are 
adjusting the temperature, then it will automatically switch to 
display the actual temperature when you have finished setting the 
temperature. 
5. 
Set the temperature using the up/down Solder iron buttons ,"5" 
from the panel 
6. 
Start using when real temperature reaches the set temperature. 
15 