PACKAGE INCLUSION
Nozzles
Notice ***
732 Main Station
Lamp
SPECIFICATIONS*
Power Input:
Available in 110V 21Amps / 220V 11 Amps (Max)
Main Unit: 520(l) x 370(w) x 410(h) mm
Dimensions:
Board Holder:450(l) x 280(w) x 134(h) mm
Total : 2100 Watts Maximum
Power
Top Heater: 500 Watts
Consumption:
Bottom Heater: 1500 Watts
Solder Iron: 75 Watts
Temperature Range:
50°C 280°C (^maximum)
Weight:
Approx. 11.6 Kg
Top Heater: Forced Convection Quartz Infrared
Heating Element:
Bottom Heater: Quartz Infrared
Solder Iron: Ceramic heater
Top Heater: 60 x 60 mm
PreHeating Area:
Bottom Heater: 310 x 310 mm
^Depends on type of operation
*Specifications subject to change without prior notice
*** Expansion for future versions, may not be available for current releases.
6
Soldering Iron
Soldering Iron
stand
Temperature
probe
Vacuum Suction
Pen
Others:
Flux.
Instruction
Spatula.
Manual
OPERATING PROCEDURES
This type of operation utilizes the external temperature probe A to regulate
the top heater, while the external temperature probe b regulates the heat of the
bottom heater. Using this type of operation allows us to closely control the
temperature at board level. While freeing up external temperature probe C for
additional monitoring.
1.
To set the desired top heater temperature press the selection button
repeatedly until the top display shows "TOP" and the middle display shows
"SEt" . The bottom display would show the current set temperature of the top
heater followed by a suffix "A".
2.
Press the increase or decrease button to adjust the top heater set
temperature level. The set temperature is adjustable from 50 to 280 C in this
type of operation. To temporarily turn off the top heater simultaneously press
both the "Increase" and "decrease" button
display see page 8)
. The bottom display will show "OFF" indicating the top
heater is now turned off.
3.
To set the desired bottom heater temperature press the selection button
repeatedly until the top display shows "bOt" and the middle display shows
"SEt" . The bottom display would show the current set temperature of the
bottom heater followed by a suffix "b".
4.
Press the increase or decrease button to adjust the bottom heater set
temperature level. The set temperature is adjustable from 50 to 280 C in this
type of operation. To temporarily turn off the bottom heater simultaneously
press both the "Increase" and "decrease" button
panel display see page 8)
. The bottom display will show "OFF" indicating the
bottom heater is now turned off.
(type 1)
5.
For this type
of operation we must closely monitor the actual
temperature of the Top heater external temperature probe A and the
external temperature probe b. As this two probes manage the heat of both
the top and bottom heater.
(#3 & #4 from the control panel
(#3 & #4 from the control
11