Datatool S4 User Manual
Hide thumbs Also See for S4:

Advertisement

USER GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Datatool S4

  • Page 1 USER GUIDE...
  • Page 2: Registering The System

    Welcome Registering the system Thank you for choosing the new Datatool S4 Alarm ® system for your motorcycle. The system provides many unique features designed to increase the protection In order to activate the provided warranty cover for your of your machine or to customise its operation to meet new alarm system, please either return the completed your individual requirements.
  • Page 3: Your Remote Control

    Your remote control All S4 systems come supplied with 2 remote controls as standard. It is possible to add up to 4 extra remote controls (6 in total). The picture below show the type of transmitter supplied with your alarm.
  • Page 4 Changing your remote control battery Each remote control contains a single long-life lithium battery (CR1616). This battery will normally last at least 12 months. Normal range for the remote control is around 10 metres. As the battery within the remote control comes to the end of its life, you will notice a reduction in its range and the battery should be replaced.
  • Page 5: Operating The Alarm System

    FULL passive arming arms the immobiliser and ignition trigger only. of both the alarm and immobiliser (except on the S4 Green model) 45 seconds after turning off the ignition. If you wish to make the alarm fully arm passively you...
  • Page 6: Disarming The System

    The system will still have immobilised the machine coded into the system. This ensures you will always (except with S4 Green model) and the alarm will react know you are in possession of all remote controls if the machine is hot-wired, the supply to the alarm capable of operating your system.
  • Page 7: Automatic Rearming

    The system will arm or disarm for this one operation and only flash the indicators. All S4 Alarm systems store the last five triggers NOTE: The inclusion of the arm and disarm indication within their memory. This can only be accessed by an beeps is strictly forbidden in all EU countries.
  • Page 8: Sleep Mode

    Switching Point 9.8 Volts extended period with the alarm armed we recommend the use of a battery conditioner (such as the Datatool • The LED is switched off (does not flash). Smart Charger) to maintain the battery charge level.
  • Page 9: Winter Mode

    We would again advise you on the benefits of using the conjunction with a Thatcham approved ground anchor. Datatool Smart Charger to maintain the condition of your battery during extended stand up periods. NOTE: The machine’s battery will still naturally NOTE: Scorpion Automotive Ltd.
  • Page 10 The PIN override system digit of the required PIN and turn the ignition OFF All Datatool S4 Alarms have a PIN disarming feature. ® As a new product there is no PIN number programmed and ON. into the alarm, therefore we strongly recommend you 8.
  • Page 11: Entering A New Pin Code

    Entering a new PIN code To initialise the PIN number the following procedure should be followed: Ignition Ignition Ignition Ignition Ignition ON within 5 secs Press both buttons LED on bike simultaneously within 10 seconds flashes rapidly confirmation beep 3 secs for 3 seconds ONE LONG TONE Repeat procedure to confirm new PIN...
  • Page 12 Disarming the system with your PIN If the transmitter is lost or damaged, or the transmitter battery is flat, the system can be overridden by your If entered correctly, the alarm will disarm and the chosen four digit PIN (Personal identification Number) motorcycle indicators will flash once.
  • Page 13 Enter the PIN number as previously described. Lost or stolen remote controls can be removed from your system by any APPROVED Datatool dealer. ® e) When the PIN number has been entered correctly,...
  • Page 14: Customising The System

    Customising the system 2. Press the BLACK button on the remote control to It is possible to change the operation of the security system to suit your requirements (see transmitter learn move backwards through the table to Switch 1 procedure for details on how to enter the software (one beep will be heard when the switch located).
  • Page 15 Changing the passive arming 3. Once you have set the alarm to your arming preference, press BOTH buttons of the remote settings (passive immobiliser or control to accept the setting, a double beep will be heard and you will return to the software switch full passive arming) selection.
  • Page 16: Special Features

    Special features (Dealer Selectable only) The factory default settings are in bold text. The following features can only be accessed by an APPROVED Datatool dealer. Should you wish to ® have a setting changed from the factory default please NOTE: The inclusion of arm and disarm indication discuss this with your dealer fist.
  • Page 17 Extending your security Extra siren/Pager output FCC: This system contains a supplementary output which This device complies with part 15 of the FCC rules. becomes positive only when the siren is sounding. This wire is identified by a green and yellow tag on the Operation is subject to the following two conditions: end.
  • Page 18: Declaration Of Conformity

    • Clean contacts on the battery and the equipment before inserting new ones. The declaration of conformity certificates applicable to the Datatool S4 range of security systems can be • Insert only the batteries which are listed in this viewed at www.datatool.co.uk user guide.
  • Page 20: Quick Reference Guide

    For full instructions on feature please refer to the main manual or visit www.datatool.co.uk DATATOOL products may be subject to change or amendment DATATOOL reserve the right for this procedure. Datatool – a brand of Scorpion Automotive Ltd Drumhead Road, Chorley North Business Park, Chorley, Lancashire, England.

Table of Contents