Installing The Control Module - Enterasys Xpedition 8000 Getting Started Manual

Hide thumbs Also See for Xpedition 8000:
Table of Contents

Advertisement

4.
Use a #2 Phillips screwdriver to tighten the captive screws on each side of the DC
power supply to secure it to the chassis.
5.
Attach wires to the terminal blocks on the front of the unit. To attach a wire, loosen the
terminal screw, insert the exposed end of the wire, and tighten the terminal screw.
6.
Connect the safety ground wire to a reliable earth ground.
7.
Connect the DC input wiring to a DC power source. See
Figure 30 on page 57
DC power source.

Installing the Control Module

The primary control module always resides in the CM slot. If you need to replace the
primary control module in the CM slot, or you want to install a redundant control module
in slot CM/1, use the following procedure. You will need a #2 Phillips screwdriver to
perform this procedure.
The primary control module must be installed in slot CM. The redundant control module
must be installed in slot CM/1. (See Chassis
slots.)
Figure 31
the figure describes how to do this.
Card Guides
Circuit Card
Metal Plate
Enterasys Xpedition 8000/8600 Getting Started Guide
for a diagram of the wiring connections between the XP and a
shows an example of how to install a control module. The procedure following
G8M-CM
10/100 Mgmt
Console
SSR-8
Figure 31. Installing a Control Module
Figure 29 on page 57
on page 10
for information about the chassis
CONTROL MODULE
Installing the Hardware
and
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xpedition 8600

Table of Contents