If You Experience This Difficulty...
The control module is not active.
No line cards are active.
A specific line card is inactive.
The chassis LEDs indicate activity but
you cannot tell what the XP is doing.
An older software version continues to
boot instead of the newer version on a
PC card or TFTP server.
You are unable to access the
configuration commands in the CLI.
Configuration changes do not seem to
be taking effect.
Configuration changes are not
reinstated after a reboot.
98
Try this Remedy...
Check the power cable and the circuit to
which the power supply is connected.
If the power supply is working, make sure
the control module is inserted all the way
into its slot in the chassis and the captive
screws are screwed in. The control module
must be in the or /1 slot and not in a line
card slot.
Check the power cable and the circuit to
which the power supply is connected.
Make sure the line card is inserted all the
way into the chassis and the captive screws
are screwed in.
Make sure you have properly connected the
primary control module to a management
console and the console is powered on.
Use the procedure in Loading the System
Image Software
on page 92
XP to boot using newer software.
Enter the enable command to access the
Enable mode, then enter the configure
command to access the Configuration
mode.
Use the procedure in Activating the
Configuration Commands in the Scratchpad
page 95
to activate the changes.
Use the procedure in Saving the Active
Configuration to the Startup Configuration File
on page 95
to save the configuration
changes to the Startup configuration file.