Lithium Battery (Liion/Lipo/Life) Program - Skyrc Ultimate 400W 20AMP Instruction Manual

Professional balance charger / discharger
Table of Contents

Advertisement

INITIAL PARAMETER SETUP (USERS SET UP)
DEC
INC
When you start a charge process, the integral safety timer automatically starts
running at the same time. This is programmed to prevent overcharge the battery
if it proves to be faulty, or if the termination circuit cannot detect the battery full.
The value for the safety timer should be generous enough to allow a full charge
of the battery.
DEC INC
DEC INC
DEC
INC
This program sets the maximum charge capacity that will be supplied to the
battery during charge. If the delta-peak voltage is not detected nor the safety
timer expired by any reason, this feature will automatically stop the process at
the selected capacity value.
DEC INC
DEC INC
DEC
INC
The beep sounds at every time pressing the buttons to confirm your action. The
beep or melody sounded at various times during operation to alert different mode
changes. These audible sounds can be turned on or off.
DEC INC
DEC
INC
This program monitors the voltage of input battery. If the voltage drops below the
value you set the operation forcibly terminated to protect the input battery.
DEC INC
DEC
INC
You can adjust the brightness of LCD screen at the charger.
DEC INC
· 19
Ultimate 400W
LITHIUM BATTERY (LILON/LIPO/LIFE) PROGRAM

Lithium battery (LiIon/LiPo/LiFe) program

These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of
3.3V, 3.6V and 3.7V per cell. These batteries need to adopt different charge technique that is termed
constant current (CC) and a constant voltage (CV) method. The charge current varies according to the
battery capacity and performance.
The Lithium polymer battery is charged at a constant
current until it reaches the final charge voltage of 4.2 V
per cell (B). After this point the voltage is kept at a
constant level, and the residual charge takes the form
of a declining current curve (C) until the cut-off point
(D) is reached. Charge current = C/10. At this point
the battery can be disconnected from the charger, and
is ready for use.
The final voltage of charge process is also very important; it should be precisely matched with the charged
voltage of the battery. They are 4.2V for LiPo, 4.1V for Lilo, and 3.6V for LiFe. The charge current and
nominal voltage as for cell count set on the charge program must always be correct for the battery to be
charged.
When you are willing to alter the parameter value in the program, press start/enter key to make it blink then
change the value with Inc> or <Dec key. The value will be stored by pressing start/enter key once.
Ultimate 400W
V/A/Ah
V
A
Ah
A
B
C
D
4.2V
t
20 ·