Advertisement

5.5

PROGRAMMING MODE

The constants of the VS−616G5 are composed of group symbols, function Nos. and serial Nos. for
each function item as shown below. Use
display and select one by [DATA/ENTER] key. For details of the constants, refer to Table A−4
"Constants List" or Descriptive Manual for Constants.
Constants to be set/read by digital operator can be selected by setting the access level (constant
A1−01) as described below.
Table 22
A1−01
0
1
2
3
4
Constant No.
b 1 − 01
Serial No. for each
function item
Function No.
Group symbol
Constant Access Level
Name
Exclusive for monitoring
User selected constants
QUICK−START
BASIC
ADVANCED
or
key to change the group, function or name
b : Application−related constants
C : Accel/decel time setting constants
d : Frequency reference−related constants
E : Motor−related constants
F : Option−related constants
H : Control circuit terminal−related constants
L : Protection−related constants
o : Operator−related constants
Constants can be set/read in operation mode or initialize mode.
Constants cannot be set/read in programming mode or modified
constants mode.
Up to 32 constants to be set/read by digital operator can be selected.
When A1−01=01 is selected, constants specified by A2−01 to 32 can
be set/read by digital operator. Set the constant numbers in A2−01 to
32.
When constant numbers are not set in A2−01 to 32, user selected
constants by A1−01 cannot be set/read.
Constants required for quick−start operation are set/read. For details,
refer to Descriptive Manual for Constants.
Constants required for basic operation are set/read. For details, refer to
Descriptive Manual for Constants.
Constants required for advanced operation are set/read. For details,
refer to Descriptive Manual for Constants.
5
SETTING OPERATION CONDITIONS
Description
53