YASKAWA VS?616G5 Owner's Manual page 39

Yaskawa vs?616g5 inverter owner's manual
Hide thumbs Also See for VS?616G5:
Table of Contents

Advertisement

40
Table 12
Typical Operation by Digital Operator
Description
Power ON
1
⋅Displays frequency reference
value.
Operation Condition Setting
⋅Select LOCAL mode.
Forward Jog Run
2
(6 Hz)
⋅JOG run procedure
(Runs while depressing JOG
key.)
Frequency Setting
3
⋅Change reference value.
⋅Write−in set value.
⋅Select output frequency monitor
display.
Forward Run
4
⋅Forward run (15 Hz)
Key Sequence
Digital Operator Display
REMOTE LED OFF
LOCAL
REMOTE
JOG
DATA
ENTER
Digit to be changed blinks.
Change the value
by depressing
RESET
DATA
ENTER
ESC
RUN
RUN LED lights. FWD LED lights.
Frequency Ref
U1−01 = 0.00 HZ
(SEQ, REF)
Frequency Ref
000.00 HZ
Frequency Ref
015.00 HZ
Entry Accepted
Frequency Ref
015.00 HZ
Frequency Ref
U1−01 = 15.00 HZ
Output Freq
U1−02 = 0.00 HZ
Output Freq
U1−02 = 15.00 HZ
RUN
(Cont'd)