(2) Operation Check Points
Check the following items during operation.
V Motor rotates smoothly.
V Motor rotates in the correct direction.
V Motor does not have abnormal vibration or noise.
V Acceleration and deceleration are smooth.
V Current matches the load flow.
V Status indicator LEDs and digital operator display are correct.
(3) Example of Basic Operation
(a) Operation by Digital Operator
The diagram below shows a typical operation pattern using the digital operator.
2
1
Power
ON
Forward Jog Run
Fig. 15
Operation Sequence by Digital Operator
5
3
4
Forward
6 Hz
15 Hz
Forward Run
Frequency Setting
Frequency Reference Change
4
6
Forward
60 Hz
Reverse Run
Reverse
60 Hz
OPERATION
7
Stop
39