YASKAWA VS?616G5 Owner's Manual page 53

Yaskawa vs?616g5 inverter owner's manual
Hide thumbs Also See for VS?616G5:
Table of Contents

Advertisement

Description
⋅Displaying frequency reference.
⋅Displays Operation.
⋅Displays Programming.
⋅Select Programming.
⋅Change the constant name display.
(Displays Decel Time 1.)
⋅Depress DATA/ENTER key.
The value to be set blinks.
⋅Change the value to 20.0 seconds.
⋅Write−in the constant.
⋅Return to Operation.
⋅Select Operation to display frequency
reference.
54
( Example 1 )
Select QUICK−START and change the decel time 1 (C1−02) from 10.0 to 20.0 seconds while
frequency reference is displayed.
Table 23
Changing Constant Data when QUICK−START is Selected
Key Sequence
MENU
DATA
ENTER
DATA
ENTER
RESET
DATA
ENTER
MENU
DATA
ENTER
Digital Operator Display
Frequency Ref
U1−01 = 60.00 HZ
** Main Menu **
Operation
** Main Menu **
Programming
Reference Source
Terminal
Decel Time 1
C1−02 =
10.0 Sec
Decel Time 1
0010.0 Sec
Decel Time 1
0020.0 Sec
Entry Accepted
** Main Menu **
Operation
Frequency Ref
U1−01 = 60.00 HZ
Remarks
When selecting Programming,
the constant name and setting
are displayed.
After displaying Entry Accepted
for 1.5 seconds, returns to the
decel time 1 display.