Troubleshooting Communication Problems; Using The Line Analyzer In Fingerprint - Intermec PD41 Manual

Hide thumbs Also See for PD41:
Table of Contents

Advertisement

Chapter 4 — Troubleshooting and Maintaining the Printer

Troubleshooting Communication Problems

72
Printer Problems and Possible Solutions (continued)
Problem
The printout is not in
the correct position.
You can use Dump mode to verify that the printer is receiving data
correctly from the host.

Using the Line Analyzer in Fingerprint

In Dump mode, the printer runs a Fingerprint program called Line
analyzer. The Line Analyzer captures incoming characters on the
communication ports and prints them on one or more labels.
The easiest way to enter Dump mode is through Test mode or
Extended Test mode. For help, see
Testmode to Troubleshoot" on page
After the printer enters Dump mode, the printer tells you it has
entered Dump mode by printing it on a label. The printer is ready to
receive data. If you have a PD42, the Dump mode icon appears on the
screen.
While the printer is receiving data, the Ready-to-Work indicator
blinks. After a half of a second, if no more characters have been
received, the printer times out. The program considers the
transmission terminated and prints out a label.
Possible Solution
Check for errors in the software application.
Make sure the label gap sensor is clean. For
help, see
"To clean the printhead" on
page
89.
Check the position of the label gap sensor. For
help, see
"Adjusting the Label Stop Sensor"
on page
85.
Check the position of the edge guide and media
guide.
Make sure you are using the correct media.
Make sure the platen roller is clean and in good
condition. For help, see
printhead" on page
"Using Testmode and Extended
74.
PD41 and PD42 Commercial Printer User's Manual
"To clean the
89.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd42

Table of Contents