Specifi Cations - Valor Retrofire RF24IDN Installation And Owner's Manual

Valor retrofire direct vent fireplace insert
Hide thumbs Also See for Retrofire RF24IDN:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
This appliance is intended for installation into existing
masonry or factory-built, solid-fuel burning
fi replaces only.
Approvals and Codes
This appliance is certifi ed to ANSI Z21.88a-2012 /
CSA 2.33a-2012 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and the USA and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installation terminating at the roof only.
Model RF24IDN is for use with Natural Gas only.
Model RF24IDP is for use with LPG only.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes with the National Fuel Gas
Code, ANSI Z223.1 or the Canadian Installation Code
CAN/CGA-B149. Only qualifi ed licensed or trained
personnel should install this appliance.
This appliance, when installed , must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
16
Specifi cations
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370 m).
Some materials or items, although safe,
Some materials or items, although safe,
may discolor, shrink, warp, crack, peel, and
may discolor, shrink, warp, crack, peel, and
so on because of the heat produced by the
so on because of the heat produced by the
fi replace. Avoid placing candles, paintings,
fi replace. Avoid placing candles, paintings,
photos, and other items sensitive to heat
photos, and other items sensitive to heat
around the fi replace.
around the fi replace.
HOT HEARTH / FLOOR! The hearth or fl oor
HOT HEARTH / FLOOR! The hearth or fl oor
in front of the fi replace may become very
in front of the fi replace may become very
hot when the fi replace heats. Do not use the
hot when the fi replace heats. Do not use the
hearth as a seat or shelf. Solid wood fl ooring
hearth as a seat or shelf. Solid wood fl ooring
in front of the fi replace (if allowed) may
in front of the fi replace (if allowed) may
shrink during the heating season due to heat.
shrink during the heating season due to heat.
NG
LPG
Natural
Propane
0-4,500 feet*
24,000
24,000
10,500
10,500
3.95
9.5
5.0
11.0
10.5
14.0
82-580
92-260
51
30